4-205
b) Engine stopper does not operate.
* Wire color codes in parentheses ( ): SW800
➡
From Machine No.10123
SW850
➡
From Machine No.10127
Codes with no parentheses
➡
Common to both models
★
It is assumed that the starter operation is normal.
★
Measure the voltage with the starter switch ON.
6
YES
NO
1
YES
NO
Is specified voltage
present at engine
stopper terminal
that carries wire
BY(L)?
Is specified voltage
present at engine
stopper terminal that
carries wire LW?
3
A
YES
NO
5
• 20~28V
2
YES
NO
Is specified voltage
present at engine
stop relay terminal 5
that carries wire LW?
YES
NO
Is specified voltage
present at engine
stop relay terminal 3
that carries wire
L(G)?
Is specified voltage
present at engine
stopper that carries
wire L(G)?
Is specified voltage
present at engine
stop relay terminal 1
that carries wire BR?
YES
NO
• 20~28V
• 20~28V
Possible cause
Remedy
Wire BY(L) from engine stop-
per to battery relay (to branch
point) not connected or incor-
rectly connected.
Repair or renew
wires.
To "A" on this page
Wire LW from engine stopper
to engine stop relay terminal 5
not connected or incorrectly
connected.
Repair or renew
wires.
Engine stopper faulty.
Renew.
• 20~28V
• 20~28V
• 20~28V
Engine stopper faulty.
Renew.
Wire L(G) from engine stop
relay terminal 3 to engine stop-
per not connected or incorrect-
ly connected.
Repair or renew
wires.
Engine stop relay faulty
(including earth wire).
Renew.
Wire BR from engine stop
relay terminal 1 to starter
switch terminal BR not con-
nected or incorrectly connect-
ed.
Repair or renew
wires.
Troubleshooting for Electric System
Summary of Contents for SW800 Series
Page 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...SPECIFICATIONS ...
Page 8: ......
Page 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Page 12: ...MEMO ...
Page 13: ...STRUCTURE OPERATION ...
Page 14: ......
Page 32: ...2 018 ...
Page 68: ...INSPECTION ADJUSTMENT ...
Page 69: ......
Page 73: ...3 101 ...
Page 88: ...TROUBLESHOOTING ...
Page 89: ......
Page 114: ...4 219 Troubleshooting for Electric System ...