4-244
E-13 Coolant temperature gauge reads wrong
★
Other gauges and lamps operate correctly.
★
Measure the voltage with the starter switch ON.
1
2
• Repair or
renew wire.
• Repair or renew
thermo unit
mounting.
YES
NO
Is resistance of
thermo unit as
shown in table 2?
Does coolant tem-
perature gauge
indicate as shown
in table 1?
Is stated voltage
present at coolant
temperature gauge
terminal T that car-
ries wire Sb?
*Measure unit with
other parts removed.
Is stated voltage
present at thermo
unit terminal that
carries wire Sb?
YES
YES
NO
NO
4
YES
NO
3
• 3~8V
• Disconncect wire
from thermo unit.
Possible cause
Remedy
Thermo unit earth wire incor-
rectly connected or thermo
unit malfunctioning.
Thermo unit faulty.
Renew.
Coolant temperature gauge
faulty.
Renew.
• 3~8V
• Disconncect wire
from thermo unit.
Wire Sb from Coolant temper-
ature gauge to thermo unit
not connected or incorrectly
connected.
Repair or renew
wire.
Coolant temperature gauge
faulty.
Renew.
Thermo unit termi-
nal wire Sb
Gauge reading
Disconnected
Lowest
Grounded
Highest
Table 1
Thermo unit
temperature
Resistance (
Ω
)
50°C
150~158
100°C
About 27.4
Table 2
Thermo unit
Sb
Fuse
15A
YW (WL)
Sb
B
150
Ω
SW8004012
Coolant temperature gauge
−
+
T
Troubleshooting for Electric System
Electric wiring diagram for mode E-13
* Wire color codes in parentheses ( ): SW800
➡
From Machine No.10123
SW850
➡
From Machine No.10127
Codes with no parentheses
➡
Common to both models
Summary of Contents for SW800 Series
Page 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...SPECIFICATIONS ...
Page 8: ......
Page 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Page 12: ...MEMO ...
Page 13: ...STRUCTURE OPERATION ...
Page 14: ......
Page 32: ...2 018 ...
Page 68: ...INSPECTION ADJUSTMENT ...
Page 69: ......
Page 73: ...3 101 ...
Page 88: ...TROUBLESHOOTING ...
Page 89: ......
Page 114: ...4 219 Troubleshooting for Electric System ...