4-232
Troubleshooting for Electric System
h). AUTO mode is not selected.
(SW800: From Machine No.10123 SW850: From Machine No. 10127).
Is stated voltage
present at vibration
relay (4) terminal 5
that carries wire
Br?
1
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
2
NO
Is stated voltage
present at vibration
relay (4) terminal 3
that carries wire P?
3
YES
Is resistance of
vibration relay (4)
earth wire as
stated?
NO
10
Is stated voltage
present at battery
relay terminal BR
that carries wire
RB (BrY)?
YES
YES
NO
Is resistance of
vibration relay (4)
earth wire resist-
ance as specified?
• Lower than 1
Ω
• Disconnect relay
from wire.
4
YES
NO
Is stated voltage
present at starter
motor terminal 2
that carries wire
O?
Is stated voltage
present at starter
motor terminal 3
that carries wire
Gy?
5
YES
NO
YES
NO
YES
• 20~28V
• CONT/AUTO selector
switch: AUTO
NO
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
6
• 20~28V
• CONT/AUTO selector
switch: AUTO
• F-R lever: Move
forward or backward
• 20~28V
• CONT/AUTO selector
switch: AUTO
Summary of Contents for SW800 Series
Page 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...SPECIFICATIONS ...
Page 8: ......
Page 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Page 12: ...MEMO ...
Page 13: ...STRUCTURE OPERATION ...
Page 14: ......
Page 32: ...2 018 ...
Page 68: ...INSPECTION ADJUSTMENT ...
Page 69: ......
Page 73: ...3 101 ...
Page 88: ...TROUBLESHOOTING ...
Page 89: ......
Page 114: ...4 219 Troubleshooting for Electric System ...