4-221
Troubleshooting for Electric System
YES
6
YES
NO
Is resistance of job
lamp relay earth
wire as specified?
Possible cause
Remedy
Job lamp switch defective.
Renew.
Job lamp relay defective.
• Lower than 12V
7
NO
Is stated voltage
fed to job lamp
switch terminal 6
that carries wire
YB?
• 20~28V
• Set job lamp switch
to Low.
Wire RY from fuse to job lamp
switch terminals 1 and 4 not
connected or incorrectly con-
nected.
Repair or renew
wire.
Wire O from job lamp relay ter-
minal 5 to job lamps (to
branch point) not connected
or incorrectly connected.
Repair or renew
wire.
Wire YB from job lamp switch
terminal 6 to job lamp relay ter-
minal 1 not connected or incor-
rectly connected.
Repair or renew
wire.
Job lamp switch defective.
Renew.
Renew.
Job lamp switch defective.
Wire RY from job lamp switch
terminal 1 to fuse (from
branch point) not connected
or incorrectly connected.
Repair or renew
wire.
Renew.
Wire RL from job lamp switch
terminal 5 to lamps (to branch
point) not connected or incor-
rectly connected.
Repair or renew
wire.
Renew.
Job lamp relay earth wire not
connected or incorrectly con-
nected.
Repair or renew
wire.
Job lamp switch defective.
Summary of Contents for SW800 Series
Page 1: ...CONFIDENTIAL SHOP MANUAL Series ...
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...SPECIFICATIONS ...
Page 8: ......
Page 9: ...1 001 SPECIFICATIONS 1 External Views and Specifications 1 1 SW800 1 002 1 2 SW850 1 003 ...
Page 12: ...MEMO ...
Page 13: ...STRUCTURE OPERATION ...
Page 14: ......
Page 32: ...2 018 ...
Page 68: ...INSPECTION ADJUSTMENT ...
Page 69: ......
Page 73: ...3 101 ...
Page 88: ...TROUBLESHOOTING ...
Page 89: ......
Page 114: ...4 219 Troubleshooting for Electric System ...