8-024
INSPECTION AND ADJUSTMENT
14. MEASUREMENT OF VIBRATOR MOTOR CASE
PRESSURE
14-1. Measurement
CAUTION
Take care not to operate the vibratory drum for a
longer period of time than necessary with the machine
stationary. Otherwise, the vibrator bearing could be
seized.
Oil temperature during measurement : 50
± 5
°C (122
± 9
°F)
①
Remove plug from drain port (1). Attach pressure gauge
with adapter
ⓙ
.
Adapter
ⓙ
: 7/8-14UNF
Pressure gauge : 0 to 5 MPa (0 to 725 psi)
②
Apply parking brake by pressing parking brake switch
button.
③
Set vibration mode change switch to “ ”.
④
Start the engine and set throttle lever to “FULL”.
⑤
Press F-R lever vibration switch (ON).
⑥
Measure pressure when vibration select switch is in
“
” and “
”, respectively.
⑦
Press F-R lever vibration switch (OFF) as soon as
measurement is finished.
Allowable motor case pressure
: 0.17 MPa (24.7 psi) or less
•
•
•
★
SV412-08013
1
SV412-08013
1
j
PG001022
j
PG001022
Summary of Contents for SV410-2
Page 1: ...SV410 2 SHOP MANUAL 3498 6404A 0 ...
Page 2: ......
Page 4: ......
Page 13: ...SAFETY ...
Page 14: ......
Page 22: ......
Page 23: ...SPECIFICATIONS ...
Page 24: ......
Page 25: ......
Page 40: ......
Page 41: ...ENGINE AND CONTROLS ...
Page 42: ......
Page 49: ...HYDRAULIC SYSTEMS ...
Page 50: ......
Page 51: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 60: ......
Page 62: ......
Page 63: ......
Page 74: ......
Page 76: ......
Page 78: ......
Page 80: ......
Page 86: ......
Page 88: ......
Page 89: ...ELECTRICAL SYSTEM ...
Page 90: ......
Page 94: ......
Page 96: ......
Page 98: ......
Page 100: ......
Page 102: ......
Page 116: ......
Page 127: ...VIBRATORY DRUM REAR AXLE ...
Page 128: ......
Page 136: ......
Page 138: ......
Page 154: ......
Page 156: ......
Page 162: ......
Page 163: ...BRAKE ...
Page 164: ......
Page 166: ......
Page 168: ......
Page 171: ...INSPECTION AND ADJUSTMENT ...
Page 172: ......
Page 202: ......
Page 203: ...TROUBLESHOOTING ...
Page 204: ......
Page 215: ......