9-010
INSPECTION AND ADJUSTMENT
7-2. Inspection
• If measurement results indicate the pressure deviating
from standard maximum circuit pressure range, make an
adjustment in accordance with procedure described below.
①
Remove relief valve (2) from orbitrol.
②
Check removed relief valve for trapped dirt, scratches on
its seat and other abnormalities.
③
If trapped dirt is present, disassemble and clean relief
valve.
④
If a scratch or any other abnormality is found on seat,
replace relief valve.
⑤
After inspection, measure pressure again and check that
pressure reaches standard maximum circuit pressure
range.
(NOTICE)
• Carefully disassemble and reassemble after taking
steps to prevent foreign material from getting in.