10-062
TROUBLESHOOTING
2-5-21. Glow (Preheating plug) indicator lamp does not light
Reference Fig. : 2-5-5
Check point
Check/Cause
Action
1. Harness
(1) Measure resistance between glow lamp timer terminal 6
wire GL and combination meter connector terminal wire
No.47 wire GL.
Standard resistance: 10 Ω or less
(2) Measure resistance between glow lamp timer terminal 4
wire Y and starter switch terminal R1 wire Y.
Standard resistance: 10 Ω or less
(3) Measure resistance between glow lamp timer terminal 5
wire BR and fuse box terminal 10 wire BR.
Standard resistance: 10 Ω or less
• If item (1), (2) or (3) is NG, harness is faulty.
Repair or replace
harness.
2. Glow Lamp Timer
(1) When starter switch is HEAT, measure voltage between
glow lamp timer terminal 4 inlet wire Y and chassis
ground.
Standard voltage : 12 V or more
(2) When starter switch is START, measure voltage
between glow lamp timer terminal wires and chassis
ground.
• Glow lamp timer terminal 4 inlet wire Y and chassis
ground
• Glow lamp timer terminal 5 inlet wire BR and chassis
ground
Standard voltage : 12 V or more
(3) When starter switch is HEAT, measure voltage between
glow lamp timer terminal 6 inlet wire GL and chassis
ground.
Standard voltage : 12 V or more (Electricity flows for a
definite time.)
• If items (1) and (2) are OK and item (3) is NG, glow lamp
timer is faulty.
Replace glow lamp timer.
3. Combination Meter
(Glow indicator)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 57 inlet wire L and ground
terminal wire No.2 wire B.
• Starter switch terminal wire No.37 inlet wire WY and
ground terminal wire No.2 wire B.
Standard voltage : 12 V or more
(2) When starter switch is HEAT, measure voltage between
combination meter glow indicator lamp terminal wire
No. 47 outlet wire GL and ground terminal wire No.2
wire B.
Standard voltage : 12 V or more (Electricity flows for a
definite time.)
• If above items (1) and (2) are OK and glow indicator lamp
does not light, combination meter is faulty.
Replace combination
meter.
Summary of Contents for R2H-2
Page 1: ...R2H 2 SHOP MANUAL 3498 66344 0 ...
Page 8: ...SAFETY ...
Page 16: ...SPECIFICATIONS ...
Page 23: ...ENGINE AND CONTROLS ...
Page 30: ...HYDRAULIC SYSTEMS ...
Page 47: ...ELECTRICAL SYSTEM ...
Page 53: ...DRUM ...
Page 58: ...BRAKE ...
Page 61: ...WATER SPRAY SYSTEM ...
Page 63: ...INSPECTION AND ADJUSTMENT ...
Page 79: ...TROUBLESHOOTING ...