10-056
TROUBLESHOOTING
2-5-17. Water spray indicator lamp does not light
• Check that water spray pump can be operated.
Reference Fig.: 2-5-4
Check point
Check/Cause
Action
1. Harness
• Measure resistance between water spray relay terminal B
wire LW and combination meter connector terminal wire
No.19 wire LW.
Standard resistance: 10 Ω or less
• If resistance is abnormal, harness is faulty.
Repair or replace
harness.
2. Combination Meter
(Water spray indicator)
(1) When starter switch is ON, measure voltage between
combination meter terminal wires and ground terminal
wire.
• Battery terminal wire No. 57 inlet wire L and ground
terminal wire No.2 wire B
• Starter switch terminal wire No. 37 inlet wire WY and
ground terminal wire No.2 wire B
Standard voltage: 12 V or more
(2) When starter switch is ON and water spray switch is
ON, measure voltage between combination meter
water spray indicator lamp terminal wire No. 19 inlet
wire LW and chassis ground.
Standard voltage: 12 V or more
• If above items (1) and (2) are OK and water spray
indicator lamp does not turn on, combination meter is
faulty.
Replace combination
meter.