PDS33 Series
- 35 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
FD.10
Water shortage
detect time
0.0s
~
3600.0s
0.1s
0.0s
○
FD0A
FD.11
Water shortage
detect
frequency
1.00Hz
~
F0.12
0.01Hz 45.00Hz
○
FD0B
FD.12
Water shortage
detect current
percentage
0.0%
~
100.0%
0.1%
40.0%
○
FD0C
FD.13
Water shortage
restart time
0min
~
9000min
1min
20min
○
FD0D
FD.14
MPPT low
limit voltage
250.0V
~
FD.15
220V type
:
275.0V
380V type
:
480.0V
0.1V
480.0V
○
FD0E
FD.15
MPPT high
limit voltage
FD.14
~
800.0V
220V type
:
330.0V
380V type
:
580.0V
0.1V
580.0V
○
FD0F
FD.16
MPPT low
limit of output
frequency
0.0%
~
FD.17
0.1%
20.0%
○
FD10
FD.17
MPPT low
limit of high
frequency
FD.16
~
100.0%
0.1%
100.0%
○
FD11
FD.18
MPPT fast
speed down
rate
0
~
200
1
20
○
FD12
FD.19
MPPT fast
speed down
time
0.0s
~
3600.0s
0.1s
0.5s
○
FD13
FD.20
MPPT start
disturbance
voltage initial
value
0.1V
~
50.0V
0.1V
20.0V
○
FD14
FD.21
MPPT given
voltgae
0.0V
~
800.0V
0.1V
/
◎
FD15
FD.22
MPPT enable
voltage
0.0V
~
800.0V
0.1V
/
◎
FD16
FD.23
MPPT open
voltage
0.0V
~
800.0V
0.1V
/
◎
FD17