PDS33 Series
- 33 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
protection gain
FA.02
Early warning
coefficient of
motor overload
protection
50%
~
100%
1%
80%
○
FA02
FA.03
Gain of over
voltage stall
protection
0
~
100
1
10
○
FA03
FA.04
Value of over
voltage stall
protection
120%
~
150%
1%
130%
○
FA04
FA.05
Gain of over
current stall
protection
0
~
100
1
20
○
FA05
FA.06
Value of over
current stall
protection
100%
~
200%
1%
150%
○
FA06
FA.07
Short to
ground
protection
0
:
Invalid
1
:
valid
1
1
○
FA07
FA.08
Auto reset
times
0
~
5
1
0
○
FA08
FA.11
Input phase
loss protection
0
:
Disabled
1
:
Enabled
1
1
○
FA0B
FA.12
Output phase
loss protection
0
:
Disabled
1
:
Enabled
1
1
○
FA0C
FC Group
:
Communication parameters
FC.00
Local address 1
~
247
,
0 for
broadcast address
1
1
○
FC00
FC.01
Baud rate
0
:
300 bps
1
:
600 bps
2
:
1200 bps
3
:
2400 bps
4
:
4800 bps
5
:
9600 bps
6
:
19200 bps
7
:
38400 bps
8
:
57600 bps
9
:
115200 bps
1
5
○
FC01