PDS33 Series
- 38 -
Function
Code
Function
Description
Unit
Factory
setting
Modification
Type
Communicati
on Address
current fault
E0.07
Controller’s
status record of
current fault
-
-
-
◎
E007
E0.08
Time record of
current fault
(
Calculated
from powering
on
)
-
-
-
◎
E008
E0.09
Time record of
current fault
(
Calculated
from starting
)
-
-
-
◎
E009
Parameter interpretation:
F0.01, Start/Stop Mode Option: If set to 0, start-stop control of keyboard panel, if
set to 1, the external terminal control start-stop, DI1 and COM conduction start,
disconnected to stop;
F2.01-F2.05,Motor parameter: the user can set according to the actual pump motor
nameplate parameters
FE.00 user password: the user can set a 5 digits password; after the password is set
up and confirmed, the password will be valid for a minute.
FD.07, Automatic start when power on: the factory defaults to 0 (disabled). It can
be set to 1 (enabled), then as long as the solar module power supply, the controller
will automatically start and achieve automatic operation of the whole day.
FD.10 water shortage detection time: when applied to a deep well pump, not using
the water level probe to detect the water shortage, the controller can use the
built-in water shortage detection function to complete the water shortage detection.
When this parameter is not 0, the software will start the function of water shortage.
Software shortage detection principle: If the water shortage happens, the controller