8000m Series
- 123 -
FB.05
Roller perimeter for fixed
length control
Factory Setting
100cm
Setting Options
0~9999cm
Set roller perimeter which refers to 1 pulse of discrete signal per round to the
multi-function digital input terminal of VFD.
Length counting displaying by VFD=Roller perimeter
×
accumulation of pulses.
FB.06
Fixed length setting
Factory Setting
1000m
Setting Options
0~9999m
Set the target fixed length, as the displaying length reached this setting or 9999m,
it means the fixed length control is over and the VFD will display “FULL” and
stop. To clear the accumulated length value and fault please press STOP key.
FB.07
Clear length value
Factory
Setting
0
Setting Options
0 No
operation
1 Clear
This parameter is for the operation of clearing current length value, and after
clearing operation the parameter will be reset to 0 automatically.
FB.08
Counter value setting
Factory Setting
0
Setting Options
FB.09~9999
FB.09
Designated counter value
Factory Setting
0
Setting Options
0~FB.08
FB.10
Length unit selection
Factory Setting
0
Setting Options
0
Actual counting length =
displayed length* 1m
1
Actual counting length=
displayed length* 10m