8000m Series
- 35 -
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
F2.06
Motor stator
resistance
0.001~65.53
Ω
0.001
Ω
○
F2.07
Motor rotator
resistance
0.001~65.53
Ω
0.001
Ω
○
F2.08
Motor stator
inductance
0.1~6553mH 0.1mH
○
F2.09
Motor rotator
mutual inductance
0.1~6553mH 0.1mH
○
F2.10
Motor no-load
current
0.1~655.3A A
○
F2.11 Reserved
F2.12 Reserved
F3 Group: Vector Control Parameters
F3.00
Proportional gain 1
of speed loop
0~100
20
○
F3.01
Integral time 1 of
speed loop
0.01~10.00s 0.01s
0.50s
○
F3.02
Low frequency
point of switch
0.00Hz~F3.05 0.01Hz
5.00Hz
○
F3.03
Proportional gain 2
of speed loop
0~100 1
25
○
F3.04
Integral time 2 of
speed loop
0.01~10.00s 0.01s
1.00s
○
F3.05
High frequency
point of switch
F3.02~F0.10 1Hz
10.00Hz
○
F3.06
Coefficient of slip
compensation at
VC control mode
50~200% 1%
100%
○
F3.07 Upper limit torque
0.0 ~200.0% (Drive rated
current)
0.10% 150.00%
○