6105
6105
6105
6105 Belt
Belt
Belt
Belt Feeder
Feeder
Feeder
Feeder integrator
integrator
integrator
integrator
---
---
---
--- User
User
User
User’’’’s
s
s
s Guide
Guide
Guide
Guide ---
---
---
---
3
1.2
Technical
Technical
Technical
Technical Specifications
Specifications
Specifications
Specifications
(a)
Chinese / English menu
(b)
Weighing Capability
· The 6105 integrator is capable of connecting up to eight 350
Ω
loads and acquiring a speed signal
from the speed sensor, to calculate flow rate and total.
· The 6105 integrator has the function of automatic zero calibration.
(c)
Ambient Environment
· Location: Indoor or outdoor, as close as possible to the load cells, free from damp and dust.
· Temperature:
Storage temperature:
-40~+70
º
C
Operating temperature
-10~+50
º
C
· Maximum Relative Humidity: 95%
(d)
Power Requirements
·
220VAC
±
10% or 110VAC
±
10% 50Hz
·
Fuse: 2A
·
EMI / RFI filter
(e)
Load Cell
· offers 10VDC(+/-10%), 500mA excited power, up to 8 load cells
· Sensitivity: 0.5mV/V ~ 3.5mV/V
· Max. input signal 33mV
· Load cell shield grounding
· Excitation compensation circuit is employed when the cable distance is over 60 meters but less
than 900 meters.
· Local or remote compensation can be selected by a jumper set.
(f)
Mainboard Digital Input
The mainboard provides 6 programmable inputs for receiving dry contact on-off signal
(g)
Mainboard Digital Output
The mainboard provides 8 programmable outputs.
(h)
Outline Dimensions
Panel mount:
Outliner dimensions: 288mm x 144mm x185mm
Front panel dimensions: 284mm x140mm
Field mount:
Outline dimensions: 312mm x 380mm x 150mm
Mounting hole dimensions: 240mm x 450mm