6105
6105
6105
6105 Belt
Belt
Belt
Belt Feeder
Feeder
Feeder
Feeder integrator
integrator
integrator
integrator
---
---
---
--- User
User
User
User’’’’s
s
s
s Guide
Guide
Guide
Guide ---
---
---
---
61
4.2.1
4.2.1
4.2.1
4.2.1
Power
Power
Power
Power Supply
Supply
Supply
Supply Examination
Examination
Examination
Examination
Measure the AC voltage at the output terminal of the transformer using the two probes of the AC
voltmeter. Check that the measurement is in line with that specified on the transformer.
4.2.2
4.2.2
4.2.2
4.2.2
Speed
Speed
Speed
Speed Input
Input
Input
Input
Check speed input signal according to the flowchart in Figure 6-2. This examination should be
performed after the belt scale is powered on and has been running in normal speed. The speed signal
is in the form of pulses emitted by the speed sensor. The number of speed pulses can be learnt from
the Diagnostics menu of the 6105.
Figure 6-2
Troubleshooting the Speed Input
4.2.3
4.2.3
4.2.3
4.2.3
Load
Load
Load
Load Cell
Cell
Cell
Cell Input
Input
Input
Input
Check load cell input signal according to the flow chart in Figure 6-3 based on the following conditions:
·
Powered connected equipments
·
At normal belt speed
·
Empty load
·
Normal load cell input signal
Check that the weight indication displayed in Diagnostics menu of the 6105 integrator is between 1 and
16777216. The weight indication should be changed in the same direction as the sense of desired
result. If the weight indication is beyond the given range, there may be problems with load cell, wire
connection or CPU board. In this case, press RUN key to stop the examination of load cell input.
Start
Speed input examination
menu
→
Diagnostics
→
Observe change of speed
signal (Refer to 5.3.10)
Speed input is normal.
End
No speed input
Check speed
sensor and its
wiring
Speed input
part of CPU
board fails
Repair or replace