Technical
specifications
2022/04
Operating instructions Concept PDG 2906 peristaltic dosing pump
11 / 44
7
Technical specifications
Performance data
Flow rate rinse-aid
pump:
20 ... 500 ml/h
(with PS 138-1.6x1.6 Ri4 / 2.5 bar max.)
80 ... 2000 ml/h
(with PS 138-3.2x1.6 Ri4G / 2 bar max.)
Configuration
Device:
Buttons on device
Windows laptop
(SSC software)
Conductivity
measurement:
Inductive conductivity sensor ILFS 02
Reset dosing time
monitoring:
Increase in conductivity
Setpoint value
reached
Rinse-aid dosing
Constant
Variable
Dosing control:
Runtime
Runtime and pauses
Conductivity control two-point
Conductivity control proportional
Control programs:
1 predosing program
1 basic program
7 weekly programs / timer programs
1 special program
Electrical data
Operating voltage:
230 V ±10%
Frequency:
50 /60 Hz
Input power:
20 VA
Protection class:
IP 65
Fuse:
0.2 A fuse for device
2 A medium time-lag fuse for solenoid valve
Data storage
Consumption data
–
daily product consumption of rinse-aid pump
and solenoid valve activation time
Container empty events / container change
Error events: Dosing error / sensor failure etc.