background image

 

Sirio HH Compact 

Instruction and maintenance manual 

Page 

1

 di 24 

Instruction n° 

207

 - Rev. 4 datel 19/10/2017

 

IT 

 

Copyright © 2017TecmecS.r.l. 

Translated from the ORIGINAL instructions

 

 

 

Sirio HH 

Compact 

 

Code. 012633  

  Code. 012634   

 

Code. 012635

 

Instruction and maintenance manual 

Summary of Contents for 012633

Page 1: ...d maintenance manual Page 1 di 24 Instruction n 207 Rev 4 datel 19 10 2017 IT Copyright 2017TecmecS r l Translated from the ORIGINAL instructions Sirio HH Compact Code 012633 Code 012634 Code 012635 Instruction and maintenance manual ...

Page 2: ...AND SAFETY DEVICES 8 3 5 RESIDUAL RISKS 8 3 6 SYMBOLS SHOWN ON THE EQUIPMENT 9 3 7 INTENDED USE OF THE EQUIPMENT 9 3 8 NON INTENDED USE 9 4 TRANSPORT AND HANDLING 10 5 INSTALLATION 11 6 OPERATING 14 6 1 OPERATION INSTRUCTION AND ELECTRICAL PANEL ADJUSTMENT 14 6 2 CUSTOMIZED AGITATION AND PAUSE SETTINGS 15 6 3 MODIFICA DELLA MODALITÀ DI FUNZIONAMENTO ERRORE IL SEGNALIBRO NON È DEFINITO 6 4 LOADING ...

Page 3: ...TECMEC S r l Località Faustina 63 20080 Albairate MI Italy Tel 39 02 9469871 Fax 39 02 94698741 e mail tecmec tecmec com web www tecmec com 1 2 Product identification The identification label is located o the left side of the structure with the below mentioned data Safety and Health Requirements Symbols Manufacture Data CE Mark Production Year Serial Number Univocal Machine Code Motor Protection C...

Page 4: ...Sirio HH Compact Instruction and maintenance manual Page 4 di 24 Instruction n 207 Rev 4 datel 19 10 2017 IT Copyright 2017TecmecS r l Translated from the ORIGINAL instructions 1 3 CE Declaration ...

Page 5: ...essment CEI EN 60204 1 Electrical Equipment of Machines 2014 30 UE Electromagnetic Compatibility 1 5 Warranty The warranty covers free of charge the repair or replacement of the components with manufacturing defects For the condition please refer to the document containing the warranty terms inside the CD supplied with the equipment In particular the warranty will not cover any transport damage or...

Page 6: ...L instructions 2 EQUIMENT DESCRIPTION The timed dispenser HH Compact is an equipment designed for the professional sector The unique feature of this equipment is to store stow in a sheltered place the color pastes contained in suitable container cans In order to avoid accidents or injury to person or and things the equippment have to be used by trained personnel ...

Page 7: ...mented The main power supply have to be provided through an electrical panel placed on the wall near to the dispenser The maximun expected power is 0 2Kw The section of each conductor must be a minimum of 1 5 mm The main power supply line must be fitted with an efficient ground connection and complies with all the requirements in force The electrical power supply panel must be composed of a differ...

Page 8: ...gency button Press the START button 3 5 Residual risks In spite of precaution adopted in the design of the equipment to ensure safe use there may be reasonably foreseeable situation for which it has only been possible to reduce the risk without completely eliminating it Risk Precaution Injuries and or crushing during the loading and or unloading of the cans Use protective gloves and safety shoes d...

Page 9: ...d place the color pastes contained in suitable container cans not provided byTecmec closed by suitable lids provided by Tecmec 3 8 Non intended use Any other use of this equipment that are not described in this manual are considered improper and therefore prohibited In particular it is forbidden Load or unload the cans during the agitation cycle process as the drive blades are in motion During thi...

Page 10: ...the risks and residual risks is located on the front side of the motor module panel In case of needs to move an operating equipment please follow the below points always operate by following the instruction provided by existing accident prevention regulation remove the shelf s and place all the colorants cans in a appropriated place place the dispenser on a pallet move the pallets with appropriate...

Page 11: ...structions 5 INSTALLATION Warning Consider the size and weights of the various components that will be moved is fundamental constraint that the below mentioned installation steps are carried out by four 4 person A Remove the module from the box B Remove the protective cardboard placed in from of the control panel C Reposition the control panel by tighten the 4 screws ...

Page 12: ... nuts Verify that the floor where the dispenser will be installed is leveled In case the dispenser is not stable adjust the 4 fleets and lock the counter nuts If this procedure is not carried out the resault could lead to noise malfunctions abnormal wear of moving parts and pose risks to the end user E Secure the front panel using the self tapping screws F Wall mounting Add the spacer on the struc...

Page 13: ...will be positioned on the floor or against the wall the dispenser must be secured against the wall or a similar structure in order to support the weight and prevents overturning For the fixing use the provided anchors H Verify the transmission joints Lift up the plastic protection of the transmission joint and ensure the perfect coupling of the 2 half coupling Place back the protection Fixing poin...

Page 14: ...cyclical function based on the setted time Std 20 min ON 240 min OFF Ⓑ STOP BUTTON Stops the motor and the cyclical function Ⓒ EMERGENCY BUTTON Will stop the motor but will maintain the electrical panel feeded To restart the motor and the cyclical function turn the emergency button clockwise and press the start button INDICATIONS Led Mode Meaning Ⓔ Green Led fixed light Dispenser powered tension p...

Page 15: ...nd pause settings The factory setting 012245 is setted as follow 20 minutes agitation 240 minutes pause If necessary you can change these settings by doing the following disconnect the machine from the power line remove the frame from the bracket remove the cover of the panel by unscrewing the 4 rear screws following the table below close the desired contacts with jumpers of the area shown in the ...

Page 16: ...ecmecS r l Translated from the ORIGINAL instructions Pause time min Shaking time min 60 min No jumper 10 min No jumper 120 min Jumper on C 15 min Jumper on B 180 min Jumper on B 20 min Jumper on A 240 min Jumper on B C 25 min Jumper on A B 300 min Jumper on A 360 min Jumper on A C 420 min Jumper on A B 480 min Jumper on A B C ...

Page 17: ... be changed from cyclic ON OFF into timer only one stirring cycle The change of operation mode from cyclic to timer is possible by acting on the side contact jumper of the card shown in the figure In cyclic operating condition the jumper is not present open contact and in timer mode the jumper is present closed contact When the change is made follow the previous table for stirring and pause settin...

Page 18: ...ranslated from the ORIGINAL instructions 6 4 Loading and unloading of cans Add or remove the cans from the respective location only when the machined is turned off When placing the can make sure that the lid is properly positioned The reference point are 2 the spout against the anti rotation nail and the fork against the reference point ...

Page 19: ...operation phase verify that the lights on the control panel are switched off and in case of agitation that the motor will stop 2 once the procedure is done restore the equipment by pressing the green START button For any other kind of issues or doubts please contact the Customer Service Dep in Tecmec 7 2 Non use periods In case that the equipment will be switched off due to a prolonged period of n...

Page 20: ...ing then press the start button The electrical panel is not working in all or in some of the buttons Possibile tension overload Remove the power plug wait a few minutes before reinsert the plug and operate the equipment Failure on the electrical panel Replace the electrical panel The motor is turning but does not transmit the rotation to the vertical shaft Feather key missing or broken on the redu...

Page 21: ...220 15 V Frequenzy 50 Hz 60Hz Hz N Phase 1Ph N TERRA Maximum Absorbed Power 0 2 kW Protection class IP55 Noise levell 62 1 db Electrical panel Dimensions 15 x 7 x 5 cm Protection class IP54 Electrical panel protection Internal fuse 10 A Power suplly 220V 50 60Hz Keyboard membrane type with raised buttons and emergency button Indications Red led Green led Motor Asynchronous single phase S1 Rated da...

Page 22: ... and maintenance manual Page 22 di 24 Instruction n 207 Rev 4 datel 19 10 2017 IT Copyright 2017TecmecS r l Translated from the ORIGINAL instructions 10 ELECTRICAL SCHEMATIC 10 1 Wiring electrical panel standard motor single phase ...

Page 23: ...uch as pipes rubber components lubrificants solvent paints aluminum copper ferrous material etc Proceed with disposal in accordance with the current laws which may also require written communication or request for approval to the responsible authority The products which are accidentally spilled from the cans but also contaminated products as paper rags used for the cleaning must be recovered and d...

Page 24: ...S r l Translated from the ORIGINAL instructions 12 SPARE PARTS 012245 012245 M15 Electrical panel IP54 20on 240off 101997 Motor Reducer 0 18Kw 220V 50Hz 20 1 017312 Joint Ø14 Esag 12 001213 Idle Gear Ø60 001212 Gear Ø60 with hexagonal pin 008194 Central gear Ø60 with hexagonal hole 12 008202 Idle gear Ø124 008912 Coupling fork HH ...

Reviews: