background image

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected  before  shipment.  At  the  time  of  shipment,  the  carrier                              

accepts responsibility for the unit. Upon receiving the unit,      

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS

The dispenser is for indoor use only. This unit is not a toy. Children should not be supervised not to play with appliance. It should 

not be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

90°F (4°C to 32°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

FS22

FS30

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer 

Customer Service for assistance as required.

Flavor Select (FS) - 22/30

LANCER INSTALLATION GUIDE

Units are equipped with an automatic agitation system and will activate unexpectedly. Do not place hands or foreign objects in the 

ice bin. Unplug the dispenser during servicing, cleaning, and sanitizing. To avoid personal injury, do not attempt to lift the dispenser 

without assistance. For heavier dispensers, use a mechanical lift.

Automatic Agitation

®

Revision: March 2018

Lancer PN: 28-0737/04

Summary of Contents for FS 22

Page 1: ...nsory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Cleanin...

Page 2: ...ply Water pipe connections and fixtures directly connected to a potable water supply must be sized installed and maintained according to federal state and local laws The water supply line must be at l...

Page 3: ...ELECTRICAL 115 VAC 60 Hz 7 0 Amps PLAIN WATER SUPPLY Min Flowing Pressure 75 PSIG 0 517 MPA Max Flowing Pressure 125 PSIG 0 860 MPA CARBONATED WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max St...

Page 4: ...er filter recommended 6 Using Counter Cutout Template provided cut out required opening for the water syrup and CO2 lines in the designated dispenser location Lancer does NOT recommend the use of shav...

Page 5: ...installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with current regulations NOTE 1 Remove the cup res...

Page 6: ...A Oetiker Pliers C Pump Inlet B Line to Unit D Pump Outlet B C D A B C D A Tee Fitting B Line to Plain Water Inlet C Line to Water Source D Line to Remote Pump A B C A Oetiker Pliers C Pump Inlet B Li...

Page 7: ...ATTENTION A B C D A Line to Dispenser B Line to Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING A CO2 Regulator B Screwdriver C Loosened Loc...

Page 8: ...igher than 40 F 4 4 C when flow rates are set NOTE There can be up to six gray water valves on this dispenser up to four carbonated water valves and two plain water valves NOTE 4 Repeat procedure for...

Page 9: ...n the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 100 parts per million PPM chlorine e g Sodium Hypochlorite or bleach and a minimum of five gallons of...

Page 10: ...the four 4 screws that attach it to the unit 5 Prepare the Cleaning Solution 6 Soak the Ice Chute Assembly in the solution 7 Rinse and dry the Ice Chute Assembly thoroughly 8 Reinstall the Ice Chute A...

Page 11: ...K BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM PLUMBING DIAGRAM BL...

Page 12: ...12 Wiring and Plumbing Diagrams FS22 International...

Page 13: ...13 Wiring and Plumbing Diagrams FS30...

Page 14: ...14 INTENTIONALLY LEFT BLANK...

Page 15: ...onment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrig...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...