background image

4

Inspection of Drain Spider

 

The drain spider is located directly in the center of the 

ice bin under the ice shroud. The cold-plate has a cavity 

 

designed to hold the drain spider. During shipment, the 

drain spider may become dislodged from its original 

position. Prior to installing the unit, ensure the drain 

spider is in the correct position. This will prevent drain 

clog issues. Inspect the lower bin area and reach under 

the shroud to ensure the drain spider is secure in the 

cold-plate cutout. If the spider is not in place, proceed 

with the following steps.

NOTE

1. 

Remove agitator clip and pin from agitator bar.

2. 

Remove agitator bar from paddle wheel.

3. 

Remove paddle wheel.

4.  Remove ice shroud by lifting back then out of bin.

5.  Locate drain spider and reinstall in the cold-plate cavity 

where drain line exits.

6. 

Reinstall all components. Ensure agitator clip is locked.

Selecting/Preparing Counter Location

ENSURE SUFFICIENT CLEARANCE

 

FOR FILLING WITH ICE 

FS22 DISPENSER, NO ICEMAKER

ENSURE KEYSWITCH 

IS ACCESSIBLE

NOTE:

 Fill ice with 

merchandiser intact.

4. 

Unit may be installed directly on counter-top or on legs. If 

installed directly on the counter, unit must be sealed to the 

counter-top with an FDA approved sealant. If an ice maker is 

to be mounted on top of dispenser, do not install dispenser 

on legs. 

 

NSF listed units must be sealed to the counter or have 

four (4) inch legs installed.

NOTE

5.  Select a location for the remote pump deck, syrup pumps, 

CO

2

 tank, syrup containers, and water filter (recommended).

6.  Using Counter Cutout Template provided, cut out required                                                                                      

opening for the water, syrup, and CO

2

 lines in the designated 

dispenser location.

 

Lancer does 

NOT

 recommend the use of shaved or

 

flake ice in the dispenser. The ice level should not 

 

exceed the height of the metal bin wall when filled 

 manually.

NOTE

3. 

The selected location should be able to support the weight of 

the dispenser, ice and possibly an ice maker being installed 

after counter cut out is made. Total weight (with ice maker) 

for this unit could exceed 800 pounds (363.6kg).

 

Connecting lines can be run through the back of the 

dispenser or extend down through a counter cutout.

 

NOTE

 

The dispenser should only be installed in a location 

where it can be overseen by trained personnel

NOTE

1.  Select a level, well ventilated location that is in close       

proximity to a properly grounded electrical outlet, within five 

(5) feet (1.5 m) of a drain, a water supply that meets the 

requirements shown in the Specifications section found on 

the previous page, away from direct sunlight or overhead 

lighting, and has sufficient clearance for air circulation. 

2.  Sufficient clearance must be provided, if an ice maker is not 

installed, to allow filling ice compartment from a five gallon 

bucket (a minimum of 16 inches is recommended). 

 

In order to facilitate proper dispenser drainage, ensure that the dispenser is level, 

 

front to back and side to side. Place a level on the top of the rear edge of the 

 

dispenser. The bubble must settle between the level lines. Repeat this procedure 

 

for the remaining three sides. Level unit if necessary. For optimum performance 

 

place the unit at a 0° tilt. The maximum tilt is 5°.

Leveling the Dispenser:

Summary of Contents for FS 22

Page 1: ...nsory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Cleanin...

Page 2: ...ply Water pipe connections and fixtures directly connected to a potable water supply must be sized installed and maintained according to federal state and local laws The water supply line must be at l...

Page 3: ...ELECTRICAL 115 VAC 60 Hz 7 0 Amps PLAIN WATER SUPPLY Min Flowing Pressure 75 PSIG 0 517 MPA Max Flowing Pressure 125 PSIG 0 860 MPA CARBONATED WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max St...

Page 4: ...er filter recommended 6 Using Counter Cutout Template provided cut out required opening for the water syrup and CO2 lines in the designated dispenser location Lancer does NOT recommend the use of shav...

Page 5: ...installation and relocation if necessary must be carried out by qualified personnel with up to date knowledge and practical experience in accordance with current regulations NOTE 1 Remove the cup res...

Page 6: ...A Oetiker Pliers C Pump Inlet B Line to Unit D Pump Outlet B C D A B C D A Tee Fitting B Line to Plain Water Inlet C Line to Water Source D Line to Remote Pump A B C A Oetiker Pliers C Pump Inlet B Li...

Page 7: ...ATTENTION A B C D A Line to Dispenser B Line to Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING A CO2 Regulator B Screwdriver C Loosened Loc...

Page 8: ...igher than 40 F 4 4 C when flow rates are set NOTE There can be up to six gray water valves on this dispenser up to four carbonated water valves and two plain water valves NOTE 4 Repeat procedure for...

Page 9: ...n the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 100 parts per million PPM chlorine e g Sodium Hypochlorite or bleach and a minimum of five gallons of...

Page 10: ...the four 4 screws that attach it to the unit 5 Prepare the Cleaning Solution 6 Soak the Ice Chute Assembly in the solution 7 Rinse and dry the Ice Chute Assembly thoroughly 8 Reinstall the Ice Chute A...

Page 11: ...K BRN BLK YEL GRY V A L V E M O U N T I N G N O Z Z L E P A N E L I N L E T F I T T I N G S BLU BLK RED GRY S1 3 SODA1 WATER1 S1 4 S1 2 S1 1 IS1 1 IS1 2 IS1 3 VALVE HARNESS DIAGRAM PLUMBING DIAGRAM BL...

Page 12: ...12 Wiring and Plumbing Diagrams FS22 International...

Page 13: ...13 Wiring and Plumbing Diagrams FS30...

Page 14: ...14 INTENTIONALLY LEFT BLANK...

Page 15: ...onment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was purchased Comply with local regulations regarding disposal of the refrig...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: