Installation
2022/04
Operating instructions Concept PDG 2906 peristaltic dosing pump
21 / 44
Tube connection
WARNING! Escape of hazardous liquid at high pressure
Kinking the tube generates high pressure that can cause the tube to rupture and
the pumped medium to escape.
Take care that tubes are installed in the proper manner, and observe the
maximum bending radius.
Please note the following points:
•
Tube diameter and tube length should be selected so that the total pressure within the
tube system (pump tube and supply tube) and, if applicable, the installation does not
exceed the maximum permissible value (see “Technical specifications” section).
•
Connect tubes to the corresponding connections in the proper manner.
•
Connect the suction line and pressure line correctly. Observe the markings
and
on
the tube kit.
Electrical installation
Danger of death, electricity
Before opening the device housing, disconnect the power supply to the
device and make sure it cannot be switched back on.
Irreparable damage to the device!
All AC voltages connected to the device must be in phase!
Important information
The following points must be strictly observed.
•
The electrical installation may only be carried out by an authorised
electrician.
•
The relevant standards, safety regulations, and the mains connection
conditions issued by the local power supply companies must be
observed!
•
If the dosing system is connected to a 230 V mains independent of
the machine, an all-pole disconnector must be provided in the power
supply line!