Proc Sheet 1 32
myC5-2v, myC5-2m
5HPRYHDQG3ODFH
)/$3XSSHUKRXVLQJ
1/2
2XWLOODJHV
- Tweezers.
- Cross shaped screwdriver.
- Fixture to positioning the metal dome PN
1%66(
6$*(0
- Plectrum.
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc Sheet 0 01
).
2. Remove mobile lower housing (
Proc Sheet 1 01
).
3. Remove equipped electronic board (
Proc Sheet 1 18
).
4. Remove the keypad (
Proc Sheet 1 04
).
5. Remove mobile upper housing (
Proc Sheet 1 13
).
5HPRYDOSURFHGXUH
1. Remove the two screw cover ( 1 ) with tweezers.
2. Remove the left and right screw cover ( 2 ) with tweezers.
3. Remove the four fixing screw of the FLAP ( 3 ).
4. Lift delicately the upper casing of the FLAP beginning from the bottom until the complete removal ( 4 ).
3ODFHPHQWSURFHGXUH
1. Place the new assembled FLAP upper housing in its area, then press the bottom until the assembly is
complete ( 5 ).
2. Position and screw :
0.08NM +/- 0.01NM
the four fixing screw ( 3 ).
3. Place the left and right FLAP screw cover ( 2 ).
4. Place the two flip stop of the FLAP ( 1 ).
)XUWKHURSHUDWLRQ
1. Place mobile upper housing (
Proc Sheet 1 13
).
2. Place the keypad (
Proc Sheet 1 04
).
3. Place equipped electronic board (
Proc Sheet 1 18
).
4. Place mobile lower housing (
Proc Sheet 1 01
).
5. Place the battery (
Proc Sheet 0 01
).
Risk of the procedure :
•
Damage the FLAP housing.
•
Damage the FPC.
Procedure
Symptom
Test
REF MTB DTS 1- Indice A - December 16 2005
Page 5-26