Proc Sheet 2 07
myC5-2v, myC5-2m
5HPRYHDQG3ODFH
7KH/&'PRGXOH
1/2
7KLVRSHUDWLRQPXVWEHPDGHDIWHU6$*(0OLFHQVH
7RROV
- Tweezers.
- Metal dome positioning fixture PN
1%66(
6$*(0
3UHOLPLQDU\RSHUDWLRQ
1. Remove the battery (
Proc Sheet 0 01
).
2. Remove mobile lower housing (
Proc Sheet 1 01
).
3. Remove equipped electronic board (
Proc Sheet 1 18
).
4. Remove the keypad (
Proc Sheet 1 04
).
5. Remove mobile upper housing (
Proc Sheet 1 13
).
6. Remove FLAP upper housing (
Proc Sheet 1 32
).
7. Remove the two in one receiver (
Proc Sheet 2 05
).
8. Remove the vibrator (
Proc Sheet 2 06
).
5HPRYDORSHUDWLRQ
1. Remove the module LCD ( 1 ).
2. Take off the module LCD and its FPC from the FLAP lower housing ( 2 ).
3ODFHPHQWRSHUDWLRQ
1. Place the new FPC on the module LCD ( 3 ).
2. Position the FPC of the module LCD ( 4 ) and then position the module LCD in its area ( 1 ).
)XUWKHURSHUDWLRQ
1. Place the vibrator (
Proc Sheet 2 06
).
2. Place the two in one receiver (
Proc Sheet 2 05
).
3. Place FLAP upper housing (
Proc Sheet 1 32
).
4. Place mobile upper housing (
Proc Sheet 1 13
).
5. Place the keypad (
Proc Sheet 1 04
).
6. Place equipped electronic board (
Proc Sheet 1 18
).
7. Place mobile lower housing (
Proc Sheet 1 01
).
8. Place the battery (
Proc Sheet 0 01
).
Risk of the procedure :
•
Stripe the lower and upper housing.
Obligation of the procedure :
•
&KDQJHRIWKHWZRLQRQHUHFHLYHUDQGWKH
)3&LIFKDQJH)/$3ORZHUKRXVLQJ
Procedure
Symptom
Test
REF MTB DTS 1- Indice A - December 16 2005
Page 5-35