Proc Sheet 1 05
myX-3 & myX-5
REMOVING / REPLACING THE METAL DOME
2/2
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002
Page 5-22
4.46 Tools :
- A 0.6mm torx screwdriver
- Gloves
- Metal dome Jig
Tweezers
4.47 Preliminary operation
This procedure must be performed by a technician with gloves.
1. Remove the back cover (
Proc sheet 0 01
).
2. Remove the battery (
Proc sheet 0 02
).
3. Remove the front cover (
Proc sheet 0 03
).
4. Unscrew the six attachment screws on the electronic board (1)
5. Remove the assembly display
(Proc sheet 1 02) ,
then the light guide keypad
(Proc sheet 1 03)
4.48 Removal procedure :
1. Lift up the metal dome (2) on the electronic card (1) with tweezers.
4.49 Placement procedure :
Warning : The metal dome is not reusable, it must be necessarily replaced by a new metal dome,
unless the board is swapped and sent as level 3
1. Replace the metal dome on the electronic card , using the metal dome jig.
4.50 Further operations :
1. Replace the new electronic board on the assembly plate (2).(
Proc sheet 1.04
)
2. Replace the light guide keypad
(Proc sheet 1.03
)
3. Replace the assembly display (
Proc sheet 1.02
)
4. Position and tighten the six attachments screws with torx settings of 0,25 N.m.
5. Replace the front cover (
Proc sheet 0 03
).
6. Replace the battery (
Proc sheet 0 02
).
7. Replace the back cover (
Proc sheet 0 01
).
8. Carry out the radio test (
Test Sheet 06
).