Proc Sheet 1 10
myX-3 & myX-5
REMOVING / REPLACING THE VIBRATING
DEVICE
1/2
Ref. SCT U38 SSC DTS 009 – Index B - December 12 , 2002
Page 5-33
4.71 Tools :
- A 0.6mm torx screwdriver
- Tweezers
4.72 Preliminary operation :
1. Remove the back cover (
Proc sheet 0 01
).
2. Remove the battery (
Proc sheet 0 02
).
3. Remove the front cover (
Proc sheet 0 03
).
4. Unscrew the six attachment screws on the electronic board.
5. Remove the assembly display , then the light guide keypad
(Proc sheet 1 02 / 1 03)
6. Remove the electronic board.(
Proc sheet 1 04
)
4.73 Removal procedure :
1. With tweezers, remove the vibrating device (1) .
4.74 Placement procedure :
1. Place the vibrating device (1) into position on the plate (2), respecting the foolproof device.
4.75 Further operations :
1. Remove the electronic board on the assembly plate. .(
Proc sheet 1 04
)
2. Replace the light guide keypad
(Proc sheet 1.03
)
3. Replace the assembly display
(Proc sheet 1 02)
4. Position and tighten the six attachments screws with torx settings of 0,25 N.m.
5. Replace the front cover /battery / back cover (
Proc sheet 0 01 / 0 02 / 0 03)
.
6. Carry out the radio test (
Test Sheet 06
).