Advanced Program Group
(continued)
56
A428 [DB Duty Cycle]
Related Parameter(s):
A427
Stop drive before changing this parameter.
Selects the duty cycle allowed for an external dynamic braking resistor when
A427
[DB Resistor Sel] is set to 3. This parameter applies only to
Frame C drives.
Values
Default
5%
Min/Max:
1/99%
Display:
1%
A433 [Start At PowerUp]
Stop drive before changing this parameter.
Enables/disables a feature that allows a Start or Run command to automatically cause the drive to resume running at commanded speed after
drive input power is restored. Requires a digital input configured for Run or Start and a valid start contact.
ATTENTION:
Equipment damage and/or personal injury may result if this parameter is used in an inappropriate application. Do
not use this function without considering applicable local, national and international codes, standards, regulations or industry
guidelines.
Options
0
“Disabled” (Default)
1
“Enabled”
A434 [Reverse Disable]
Related Parameter(s):
d006
Stop drive before changing this parameter.
Enables/disables the function that allows the direction of motor rotation to be changed. The reverse command may come from a digital
command, the keypad or a serial command. All reverse inputs including two-wire Run Reverse will be ignored with reverse disabled.
Options
0
“Rev Enabled” (Default)
1
“Rev Disabled”
A435 [Flying Start En]
Sets the condition that allows the drive to reconnect to a spinning motor at actual RPM.
Options
0
“Disabled” (Default)
1
“Enabled”