VG5 SPECIFICATIONS (continued)
Contr
ol
Char
ac
teri
st
ic
s
Control Method
Sine wave PWM
Starting Torque
150% below 1Hz (150% at 0 rpm with PG)
Speed Control Range
100:1 (1000:1 with PG)
Speed Control Accuracy
±0.2% (±0.02% with PG)
Speed Response
5Hz (30Hz with PG)
Torque Limit
Can be set by parameter: 4 quadrant control
Torque Accuracy
±5%
Torque Response
20Hz (40Hz with PG)
Frequency Control Range
0.1 to 400 Hz
Frequency Accuracy
Digital command: 0.01%, Analog command: 0.1%
Frequency Setting
Resolution
Digital Operator Reference: 0.01Hz
Analog Reference: 0.03Hz (@60Hz)
Output Frequency
Resolution
0.01 Hz
Frequency Setting Signal
-10 to +10V, 0 to +10V, 4 to 20mA
Accel/Decel Time
0.0 to 6000.0 sec.
(Accel/Decel time setting independently, 4 steps available)
Braking Torque
Approx. 20%
Pr
otec
tiv
e F
unc
tions
Motor Overload Protection
UL-recognized electronic thermal overload relay (I
2
T)
Instantaneous Overcurrent
Motor coasts to stop at approximately 200% rated output current. (CT Rating)
Fuse Protection
Motor coasts to stop at blown fuse.
Overload
Motor coasts to stop after 1 min. at 150% rated output current. (CT Rating)
Overvoltage
Motor coasts to stop if converter output voltage exceeds 410VDC (820VDC at 460V input, 1040VDC at 575V input)
Undervoltage
Motor coasts to stop if converter output voltage drops below user adjustable value
Momentary Power Loss
Immediately stop after 15 ms or longer power loss. (Continuous system
operation during power loss less than 2s is equipped as standard.)
Heatsink Overheat
Thermistor - OH1, OH2
Stall Prevention
Stall prevention during acceleration, deceleration and constant speed operation
Ground Fault
Provided by electronic circuit (overcurrent level)
Power Charge
Indication
Charge LED stays on until bus voltage drops below 50VDC
Input Phase Loss
Single-phase protection
En
vi
ron
m
ental
Co
ndi
tio
ns Location
Indoor (protected from corrosive gases and dust)
Ambient Temperature
+14 to 104°F (-10 to 40°C) for NEMA 1 type
+14 to 113°F (-10 to 45°C) for Open Chassis type
Storage Temperature
-4 to 140°F (-20 to 60°C)
Humidity
95% RH (non-condensing)
Vibration
9.8m/s
2
(1G) less than 20Hz, up to 1.96m/s
2
(0.2G) at 20 to 50Hz
Chapter 1 - Receiving & Installation
Specifications
Summary of Contents for CIMR-VG5
Page 2: ...2 VG5 Installation Quick Start Manual This page intentionally left blank...
Page 36: ...36 VG5 Installation Quick Start Manual This page intentionally left blank...
Page 60: ...60 VSG5 Installation Quick Start Manual This page intentionally left blank...
Page 113: ...VG5 Installation Quick Start Manual 113 This page intentionally left blank Appendix Notes...