Operation by Control Circuit Terminal Signal
The diagram below shows a typical operation profile using the control circuit terminal signals.
Typical Operation Example by Control Circuit Terminal Signal
Description
Key Sequence
Digital Operator Display
Figure 16 Operation Sequence by Control Circuit Terminal Signal
Power ON
Frequency Setting
Operation
Forward
60Hz
Stop
1
2
3
4
c
Power ON
· Displays frequency reference value
.
REMOTE mode is preset at the factory.
Output Frequency Display
· Switch to output frequency display.
Forward Jog Run (6Hz)
· Close between control circuit terminals 1 &
11, and 7 & 11 closed to perform JOG run.
Run & FWD LEDs illuminate.
· Open between terminals 1 & 11, and 7 & 11
after verifying JOG operation
d
Frequency Setting
· Input frequency reference via terminal 13
(voltage) or 14 (voltage/current) and verify
the input value with the digital operator.
Output Frequency Display
· Select output frequency monitor display.
e
Forward Run
· Close between terminals 1 & 11 to perform
forward run.
f
Stop
· Open between terminals 1 & 11 to stop
operation. Stop LED illuminates.
Frequency Ref
REMOTE LED (SEQ, REF) ON
U1-01 = 0.00 Hz
Output Freq
U1-02 = 0.00 Hz
Output Freq
U1-02 = 60.00 Hz
Output Freq
U1-02 = 0.00 Hz
Output Freq
U1-02 = 6.00 Hz
Frequency Ref
U1-01 = 60.00 Hz
Output Freq
U1-02 = 0.00 Hz
Chapter 2 - Operation
Trial Operation
Summary of Contents for CIMR-VG5
Page 2: ...2 VG5 Installation Quick Start Manual This page intentionally left blank...
Page 36: ...36 VG5 Installation Quick Start Manual This page intentionally left blank...
Page 60: ...60 VSG5 Installation Quick Start Manual This page intentionally left blank...
Page 113: ...VG5 Installation Quick Start Manual 113 This page intentionally left blank Appendix Notes...