LRF 7047- Integrator Manual
914929_TML_LRF7047_en_Version B
Public: 04.2019
Confidential & Proprietary
Safran Vectronix AG – All rights reserved
Page: 49/72
6.5.8 Continuous Range Request >LM,Mt,x*<CS><CR>
This command initiates a range request with predefined repetition rate.
The parameter x can take the following values:
x=0
Continuous range STOP.
x=1
Repetition rate of 1 Hz.
x=2
Repetition rate of 3 Hz.
x=3
Repetition rate of 5 Hz.
x=4
Repetition rate of 10 Hz.
Continuous range command and response
Command
Inputs
Description
>LM,Mt,x*<CS><CR>
>LM,Mt,4*E6
<0D>
Continuous range request with parameter x repetition rate.
Example with x=4, repetition rate of 10Hz.
Response
Outputs
Description
>LM,Mt,range1,range2,range3,timestamp*<CS><CR>
Every 0.1 seconds…
>LM,Mt,v0004252,R000E301,R000E301*53
<0D>
Response of LRF module to the host with parameter x.
Example with x=4, repetition rate of 10 Hz.
Table 10: 10 Hz continuous range request command
Example of a successful 10 Hz continuous range request command transaction:
Host
LRF Module
Command frame:
>LM,Mt,6*E6
<0D>
LRF Module
Host
Acknowledge frame:
>AC*84
<0D>
Response frame:
>LM,Mt,v0006404,v0090656,v0077726,t018692980*1C
<0D>
>LM,Mt,v0006406,v0090981,v0087450,t018758928*1F
<0D>
>LM,Mt,v0072447,v0085329,v0074191,t018862206*16
<0D>
>…
Host
LRF Module
Command frame:
>LM,Mt,0*E2
<0D>
Acknowledge frame:
>AC*84
<0D>
Prompt:
<