LRF 7047- Integrator Manual
914929_TML_LRF7047_en_Version B
Public: 04.2019
Confidential & Proprietary
Safran Vectronix AG – All rights reserved
Page: 45/72
6.5.4 Laser pointer command >LM,Rp,x*<CS><CR>
NOTICE
The operation of this command requires the correct use of the software interlock functionality
described in
5.7 Pointer Interlock
and
6.5.5 Laser pointer arm command
.
This command initiates a continuous laser emission at a wavelength of 830 nm (typical).
The emitted radiation at 830 nm (typical) is coaxial with the range finding radiation at 1550 nm (typical)
and it is aligned with the mechanical interface of the module.
The module provides this functionality for alignment, pointer and maintenance purposes (no range is
measured).
Laser pointer command and response
Command
Inputs
Description
>LM,Rp,x*<CS><CR>
>LM,Rp,1*E4
<0D>
>LM,Rp,0*E3
<0D>
Laser pointer request with parameter x.
Example to switch ON.
Example to switch OFF.
Response
Outputs
Description
No response expected.
Table 6: Laser pointer command
WARNING
It relies responsibility of the integrator to provide eye safety measures.
Harm to operators and damage to equipment can occur.
NOTICE
The pointer functionality is only restricted by the device temperature.
It is recommended to operate the pointer:
At extreme temperatures (below -10°C or above 45°C) for 15 sec.
At room temperature (25°C) for 4 minutes.