LRF 7047- Integrator Manual
914929_TML_LRF7047_en_Version B
Public: 04.2019
Confidential & Proprietary
Safran Vectronix AG – All rights reserved
Page: 33/72
5.3 ESD Protection
NOTICE
CAUTION: ESD (Electro-Static Discharge) sensitive device. Permanent damage may occur on
unconnected devices subject to high energy electrostatic fields. Unused devices must be stored
in conductive foam or shunts. Personnel should be properly grounded prior to handling this
device. The protective foam should be discharged to the destination socket before devices are
removed.
Parameter
Typical
Note
All Signals
+2kV
+1kV
Human body model (HBM)
Charged-device model (CDM)
5.4 Operating Conditions
Parameter
Min
Typical Max Unit
Operating Voltage PWR_IN
8
12
42
V
Operating Voltage PWR_SAFE
3
5.0
5.25
V
Typical values are recommended for operation.