COMMAND RANGING & TELEMETRY UNIT CORTEX
Is.Rev.
Date:
© Safran Data Systems
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 20
1.6.1.
IF Reception
1.6.1.1.
Analog Reception
1.6.1.1.1. IF Stages
IF input stages
3
IF input ports
2 per input stage (Nominal & Alternate)
Input bandwidth
50 to 90 MHz (- 3 dB bandwidth)
Input impedance
50
Ω
VSWR
≤ 1.25
Isolation between channels
≥ 80 dB
Aliasing rejection
≥ 80 dB
Maximum noise level
- 20 dBm
(or No = - 96 dBm/Hz for 40 MHz noise bandwidth)
AGC range (CRT XL Quantum)
- 15 to -105 dBm
AGC range (CRT eXplorer)
- 15 to -120 dBm
AGC time constant
0.1, 1, 10, 100 or 1,000 ms
AGC mode
Analog AGC : Non coherent
Digital AGC : Non coherent before carrier acquisition
then coherent (for PM and direct PCM, in a few Hz)
1.6.1.1.2. Auxiliary Inputs
Two Auxiliary input ports allow receiving baseband or IF signals for test purposes (example: TC demodulation at
IF):
Input ports
2
Input signal
Baseband or IF signal
Input bandwidth
At baseband
: DC to 20 MHz
At IF
: 0 to 90 MHz
Input signal level
At baseband
: 0.1 to 0.5 Vpp
At IF
: 0 to - 20 dBm
AGC
No
Input impedance
50
Ω