COMMAND RANGING & TELEMETRY UNIT CORTEX
Is.Rev.
Date:
© Safran Data Systems
This document is the property of
Safran Data Systems
.
It cannot be duplicated or distributed without expressed written consent.
Page 248
4.2.7.7.
Logging Data Storage & Data Time-tagging
4.2.7.7.1. Telemetry Time-Tagging
To modify the telemetry time-tagging (Time-tag the last or first bit of each TM frame/block).
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\In-snec\CortexCRT\SetDefault\Preferences\Tmux
(x = TM chain number)
Keyword:
DateFrame
Default setting at delivery:
0
Enter
0 t
o time-tag the last bit of each telemetry frame or block; enter
1
to time-tag the first bit of each telemetry
frame or block, enter
2
to time-tag the first bit after the synchronization word
4.2.7.7.2. Logging Data Storage
To enable/disable logging data storage on the disk:
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword:
Storage
Default setting at delivery:
0
Enter
0
to disable the storage. Enter
1
to enable the storage and automatically start it when SPS starts. Enter
2
to enable the storage without starting it when SPS starts.
To change the file name and access path:
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword:
File
Dir
Default setting at delivery:
D:\ZDS\Data\Storage\Menu1\Log\Logging\LOG
The file extension for logging data is
.log
.
To change the file size:
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword:
StoreSize
Default setting at delivery:
4096
(bytes)
To change the total maximum size:
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log
Keyword:
StoreTotal
Default setting at delivery:
Not
created
To enable/disable the 1st specific additional flow storage on the disk:
Registry path:
HKEY_LOCAL_MACHINE\SOFTWARE\IN-SNEC\Cortex Station\SetDefault\Log\10
Keyword:
EnableLog
Default setting at delivery:
1