Door Station Installation Guide
45
Figure 3-59 Remove the Mounting Ears
Note
The green-yellow line in the package is for grounding.
9. Connect cables and insert the modules.
1) Connect Cable 1 and one end of Cable 2 to the corresponding interfaces of the Main Unit,
then place the Main Unit into the upper grid of the left gang box.
2) Connect the other end of Cable 2 to the input interface of Sub Module 1. Connect one end of
Cable 3 to the output interface of Sub Module 1 and insert it into the middle grid of the left
gang box.
3) Finish the wiring and inserting according to the cable number and the position shown as
below.