49
ICOP PRO HD HVR USER GUIDE
IO Alarm
• Select
Enable
next to each sensor to enable IO
alarms. An alarm is triggered when the sensor is
activated
•
Alarm type:
Select from the following options:
◦
OFF:
Disables any OSD display
◦
RECORD:
Recording/alarm starts when any
sensor in this mode is detected and stops
when sensor input is removed
◦
START RECORD:
Recording/alarm begins
when any sensor with this setting is detected
and continues when sensor input is removed
(STOP button on the monitor shall be the only
way to stop recording when triggered by the
sensor with this setting)
◦
DISPLAY ONLY:
Sensor input does not start or
stop recording, only displays text on OSD and
is stored in metadata (if DVR is recording at the
time)
•
Trigger:
Tap the Setup button to configure the
parameters specific to this type of alarm for each
selected sensor
(see Trigger Setup below)
•
Linkage:
Tap the Setup button to configure the
recording, monitor display and additional options
specific to this type of alarm for each selected sensor
(see Linkage Setup below)
Then tap the
Save
button.
After completing all of the fields for one sensor, the same
configuration can be copied to other sensors. In the
Copy
field, select which sensor’s configuration to copy. In the
To
field, select which sensor to apply the copied configuration
to, and tap the
Copy
button. Then tap the Save button.