14
OPERATION AND ADJUSTMENT
FIGURE 20
FIGURE 21
13. Adjusting Glue Pot / Glue Auger
If the glue auger is not perpendicular to the panel face it may be easily adjusted by removing the
cover from the glue hinge access opening
(FIGURE 21)
and using a 3/16” Hex Wrench to loosen
the adjusting screws
(FIGURE 22).
Using the aluminium square provided
(Figure 20),
tilt glue
pot until glue auger is perpendicular to the machine top and retighten screws.
NOTE: The auger
is factory aligned and tested however due to shipping it may have moved slightly and need
minor alignment, following these procedures. POWER MUST BE DISCONNECTED AND
GLUE POT ALLOWED TO COOL BEFORE PERFORMING THIS ADJUSTMENT.
FIGURE 22
FIGURE 23
NOTE: Hinge Access opening (FIGURE 21) also allows access to hinge pin grease fittings.
The hinge pin should be lubricated after every 40 hours of use with a high quality high
temperature grease (FIGURE 23).
Adjustment Screws
Grease Fittings
Glue Hinge Access Door