![background image](http://html1.mh-extra.com/html/safeline/sl6/sl6_manual_3321571025.webp)
25
SafeLine SL6+ v.3.9.0 EN
Parameter list
Configuration data
Code Data
Comments
Enter configuration mode
00
Enter password
* - - - - #
Default = 0000
Exit configuration mode
*00*#
Alarm codes
Code Data
Comments
P100 ID code
*01* - - - - - - - - #
P100 is always 8 digits
CPC ID code
*02* - - - - - - #
CPC 6-8 digits
Q23 ID code
*03* - - - - - - - - - - - - # Q23 is always 12 digits
Telephone numbers
Code Data
Comments
1st Phone number
*11* - - - - - - - - - #
Phone number to alarm receiver: 1-20 digits.
If calling through a switchboard, delay time
can be set by adding asterisks (*) between
leading number of the switchboard and
telephone number for the alarm call receiver.
Each asterisk (*) is equal to one second delay.
Example #1:
*11*0**1234567#
Example #2:
*11*# deletes the phone no.
2nd Phone number
*12* - - - - - - - - - #
3rd Phone number
*13* - - - - - - - - - #
4th Phone number
*14* - - - - - - - - - #
Call type
Code Data
Comments
Call type 1st number
*21* - #
Change the call type of the stored telephone
numbers:
0 = P100
1 = VOICE (default)
2 = Q23
3 = CPC
Change this only if your alarm operator uses
any of the mentioned protocols.
Call type 2nd number
*22* - #
Call type 3rd number
*23* - #
Call type 4th number
*24* - #
Call type LMS number
*30* - #
LMS (Lift Monitoring System) call type
0 = P100
3 = CPC (Only battery alarm)
5 = SMS