Other codes
Code Data
Comments
Voice station
- Integrated emergency bell
*90*
- - #
Local configuration of emergency bell voice station.
First number selects voice station (1-6).
Second number selects Off (0 = default) or On (1).
Example:
*90*21# sets voice station 2 to On
Pwd for remote configuration *91*
- - - - # Change password (default=0000).
Operator silence disconnect *92*
- #
Disconnects the call when the alarm operator has
been quiet for longer than the time set.
0 = Off (default)
1 = 30 sec
2 = 60 sec
3 = 90 sec
Fallback
*93*
- #
0 = Disabled (default)
1 = Priority PSTN
2 = Priority GSM
Simulate an alarm event
*94*
- #
Triggers an alarm event after configuration is termi-
nated.
1 = Emergency call
2 = Test alarm
3 = Battery failure
4 = Microphone/speaker failure
5 = Receipt on voice call
6 = Maintenance
7 = Main unit power failure
8 = Stuck button alarm
GSM/PSTN
- RX audio level
*96*
- #
Increases the received audio level. Is used only if the
audio level from the alarm central is to low.
0 = 0% (default)
1 = +25%
2 = +50%
3 = +75%
4 = +100%
NOTE:
SW 4.4 0 or later is required.
For PSTN, HW 1.41 or later is required.
Background level
compensation
*97*
- #
0 = Off (default)
1 = On
Reset to default settings
*99*
- #
1 = Factory standard
2 = Default P100 (The following codes will be set):
*21*0#, *22*0#, * 27*03#, *80*1#, *84*1#, *88*12#
3 = Default CPC (The following codes will be set):
*21*3#, *22*3#, *27*03#, *80*1#, *84*1#, *88*12#
4 = Default VOICE (The following codes will be set):
*21*1#, *22*1#, * 27*03#, *80*1# *84*1#, *88*12#