24
SafeLine SL6+ v.3.9.0 EN
SafeLine emergency telephone units
Example 1.
Storing of two different telephone numbers, one to be answered
by P100 code and the other one with voice. (For test facility, see
example 2.)
Configuration
examples
If at any time you need to
start over, use the factory
reset command *99*1#.
Please refer to the full
configuration setup in the
“Parameter list” as these are
merely examples.
Example 2.
SLCC (SafeLine Call Centre) and 3 day test.
1.
Start configuration:
0 0
2.
Enter P100 ID code:
* 0 1 * 4 5 6 4 5 6 4 5 #
Lift ID code (each lift must have its own unique code).
3.
Set test alarm type:
* 3 1 * 0 #
- Example: Test alarm type P100.
4.
Set number of days between test alarm:
* 2 7 * 0 3 #
- Example: 3 days between test alarm.
5.
LMS phone number:
* 1 6 * 9 8 7 6 5 4 3 2 #
(Only if using SLCC)
6.
Test alarm:
* 1 7 * 1 2 3 1 2 3 1 2 #
(For more information, please refer to parameter *17* in the
”Parameter list”)
7.
End configuration:
* 0 0 * #
1.
Start configuration:
0 0
2.
1st phone number:
* 1 1 * 1 2 3 4 5 6 7 8 #
3.
2nd phone number:
* 1 2 * 2 3 4 5 6 7 8 9 #
4.
Call type 1st number:
* 2 1 * 0 #
- Example: Answered with P100 code.
5.
Call type 2st number:
* 2 2 * 1 #
- Example: Answered as voice call.
6.
Alarm button delay:
* 8 7 * 0 3 #
- Example: 3 seconds delay.
7.
End configuration:
* 0 0 *