Unscrew retaining screws Ø10
(1)
at both ends of the counter-knife.
-
Unscrew both locking screws Ø8
(2)
.
-
Pull the counter-knife partially out of the housing. If the edge is worn, pull the counter-knife out of the
housing, give it a quarter turn, such that the new edge is pointing towards the knives, and push the counter
-
knife back into the housing.
(The counter-knife can be pulled out of the housing on the right side as well as on the left side)