English
8
54
DISPLAY
Description
1.25.6.
VA1..3 Sales
1.25.7.
BA1-CA15-Cash
1.25.8.
DA1..7-CashLess
1.25.9.
Delete value = 0 data from EVA-DTS report
Quick Reading
1.25.10.
Prolongation of response waiting time from EVA-DTS data players
Extended Time-outs
1.26.-5
Allows setting a delay between the end of beverage preparation and the display of the
"Remove cup" message to the user.
Such delay is necessary to allow a complete drainage of the liquid in the dispensing tubes.
Tube emptying time
1/5
1.27.
Enables setting of a password or modification of the current one.
The password consists of a number between 000001 and 999999.
The 0000 value (default value) means no password.
To set the password, press the UP and DOWN keys and confirm using the ENTER key.
Change Password
1.27.1.
Allows setting a password to access the programming menu.
Password prog.
1.27.2.
Allows setting a password to access the maintenance menu.
Important
If the password is lost, you will have to contact the Saeco Vending Technical Assistance
Service to regain access to the Programming Menus.
Service Password
1.28.
Enables selection of whether the entries of the programming menu should be shown fully or
only partially.
Complete menus
1.29.
It allows to select the VM's operation in case the sensor detects that the maximum level in
the drip tray has been exceeded.
Machine block:
the VM does not allow to dispense beverages if the tray is full;
Message Only:
a display message is shown but it is possible to dispense beverages (WARNING failure to
empty the tray can lead to water coming out from the machine);
DISABLED: the sensor is not being used (WARNING failure to empty the tray can lead to
water coming out from the machine);
Drip Tray warning
1.30.
Management of default values for machine configurations.
The user can create and recall his own configuration.
Default Menu
1.30.1.
It allows reverting the programmable parameters to factory preset values.
This operation does not reset the product counter.
Factory default
1.30.2.
Management of the configuration which has been created by the user
Custom Default
1.30.2.1.
Restoring the configuration which has been saved by the user on the machine
Read Custom Default
1.30.2.2.
Saving the user machine configuration
Write Custom Default