English
9
103
PUMP ERROR 1-2 or 3-4
One of the pumps is faulty. The machine is still working
but it is necessary to contact the AUTHORISED SERVICE
CENTRE.
SENSOR ERROR 1 2
It is displayed when there is a faulty temperature sensor.
Switch off the machine and contact the AUTHORISED
SERVICE CENTRE.
TEMPER. ERROR
It is displayed when one of the boiler heating elements is
faulty.
Switch
the
machine
off
and
contact
the
AUTHORISED SERVICE CENTRE.
Filter alarm
The machine needs this intervention after performing the
programmed number of dispensing cycles. The softener
maintenance is at the user’s expenses, while the cartridge
replacement is at the AUTHORISED SERVICE CENTRE
expenses.
Interventions are set according to the machine working cycles
and can be programmed by the maintenance technician.
MAINTENANCE
It is displayed when the machine needs maintenance and
after performing the programmed number of dispensing
cycles.
Switch
off
the
machine
and
contact
the
AUTHORISED SERVICE CENTRE.
Maintenance interventions are set according to the
machine working cycles and can be programmed by the
maintenance technician.
9.9
Switching Off the Machine
Programmed automatic switching-off
This is possible when the function “Automatic start-up” is
active
and
the
function
“On/Off
time”
has
been
programmed.
The machine goes in “Standby” mode at the programmed time.
Manual switching-off
This
switching-off
is
necessary
when
the
function
“Automatic start-up” is not active.
It can be obtained by setting both the power button and
the all-pole switch to “0” or by disconnecting the plug.