ENGLISH
32
10 SETUP MENU
3 ALTERNATION
Par
Description
Units
VALUES
Notes
Default Min. Max.
3.1 Alternation period
1
1
14
In systems with more than 1 pump, you
can set how often (in days) to alternate the
pump in operation.
N.B.: The alternation, as it is in days, is done
from 00:00. If a pump is running, it will not
stop to alternate. The alternation in this case
will be applied when the filtration cycle
ends.
2 CICLOS
Par
Description
Units
VALUES
Notes
Default Min. Max.
2.89
Edit band sunday (2)
00:00
Sets the start time of band 2
2.90
24:00
Sets the end time of band 2
2.91
Hz
50
Sets the rotational frequency of band 2
2.92
Edit band sunday (3)
00:00
Sets the start time of band 3
2.93
24:00
Sets the end time of band 3
2.94
Hz
50
Sets the rotational frequency of band 3
2.95
Edit band sunday (4)
00:00
Sets the start time of band 4
2.96
24:00
Sets the end time of band 4
2.97
50
Sets the rotational frequency of band 4
* There is a complete configuration for every day of the week. This manual only explains how to configure Monday
and Sunday, as a summary, but the process is the same for the other days of the week.
** When the day’s settings are complete, it allows you to copy this configuration directly to the following day,
saving time when setting every day individually.
4 BACK WASH
Par
Description
Units
VALUES
Notes
Default Min. Max.
4.1 Filter wash frequency
Hz
50
Sets the frequency of the pump(s) of
operation for the filter cleaning process
4.2 Number of pumps for
washing
1
1
8
Regardless of the number of pumps
involved in the filtration, you can set the
number of pumps that you wish to use to
clean the filter.
4.3 Filter
min
5
1
60
Operating time of the pumps involved in
cleaning the filter
VSD Magnus - [e]Magnus
VSD Magnus - [e]Magnus
Summary of Contents for VSD magnus
Page 2: ...VSD Magnus e Magnus...
Page 148: ...148 10 40 10 30 mA B V 3 50 60Hz400 Hz 50Hz10 A 11 IP 55 A 3 2 VSD Magnus e Magnus...
Page 149: ...149 2 2 1 1 x400V3 4 5 2 1 24 Vdc 9 2 1 2 8 Va2030 BACK WASH VSD Magnus e Magnus...
Page 150: ...150 BACK WASH F1 F2 POWER RUN ALARM back wash 5 VSD Magnus e Magnus...
Page 153: ...153 r a B 0 4 F12 1 5 F12 1 6 8 8 8 VSD Magnus e Magnus...
Page 161: ...161 10 90 50 75 9 6 10 1 2 9 7 9 8 9 9 9 10 9 11 9 VSD Magnus e Magnus...
Page 162: ...162 11 4 5 F01 F02 F03 F04 F06 F07 X13 BACK WASH VSD Magnus e Magnus...