17
is completely dry before putting it back in place.
(*)The foam dish situated behind of the filter is to avoid the dust entrance to the motor
- Put the filter back on its support, adjusting it to the perimeter.
- Verify the perfect state of the filter, never put the filter in place when moist or broken. The
central vacuum unit will be damaged if used without the filter.
• cLEANING THE OUTSIDE.
We recommend to clean periodically the outside of the central vacuum unit using a soft cloth
moistened in water and neutral soap, allowing it to dry completely before starting the system
again. do not use solvents, alcohol or any chemical product when cleaning the outside.
8. PROBLEM SOLvING
1. WHAT TO DO WHEN THE VAcUUm cLEANER DOES NOT SUcTION.
answer: when the appliance has been used for some time and you notice that the suction
power is weaker than before or that it does not suck at all, take the following steps:
a). First check the dust deposit and empty it. after cleaning the dust, if suction power is still
weak, clean the filter as well. The machine will work after following these steps.
b) if some inlet valves work and not others, treat them as pipe obstructions.
c) If no inlet valve sucks, whereas the floor inlet valve does, it means there is dust in the pipes.
treat it as a pipe obstruction.
d) if none of the inlet valves sucks, unplug the air inlet connection from the central vacuum unit.
if the central vacuum unit sucks, it means that the pipe has an air leakage or an obstruction
close to the central vacuum unit. Check all the inlets to find the leaking point. If you cannot find
it, contact the technical service.
e) if the central vacuum unit still does not suck, this means there is a problem with the motor.
contact the technical service.
2. WHAT TO DO WHEN THE mAcHINE cANNOT BE AcTIVATED
.
a) turn it on again, connect the socket and open the two low voltage switches.
b) if the machine has an overload protection device, press the button on the device.
c) unplug the appliance and wait 30 minutes.
d) turn it on again, connect the socket and open the low voltage switch.
e) if you still cannot turn it on, contact the repair service.
3. WHAT TO DO IF THE PIPES ARE BLOckED.
a) Please read the main points of the user guide again to check that you have followed the
indications correctly.
b) turn on the central vacuum unit and continuously open and close the air speed in the pipes
so that the blocking element is sucked inside the central vacuum unit.
c) unplug the central vacuum unit and withdraw the suction tank from it. then connect a con-
ventional vacuum cleaner to the valve inlet that does not suction.
d) if the pipe is still blocked, contact the repair department.
4. WHAT TO DO IF yOU SUck UP WATER.
a) if you accidentally suck up water with the machine, keep the central vacuum unit on for 15