Nordson Eclipse EPC-30 Series Instruction Sheet Download Page 1

Instruction Sheet

E

1999 Nordson Corporation

All rights reserved

237 546A

Issued 4/99

Manual 66--EPC30--IS--04 (formerly 46-422)

P/N 237 546A

Series EPC-30 DC-Converter Board Replacement Kit

WARNING:

Allow only qualified personnel to perform the

following tasks. Observe and follow the safety instructions in

this document and all other related documentation.

The Eclipse Series EPC-30 dc-converter board converts 24 Vdc to the

lower voltages required by other components in the pattern control unit.

Use these procedures to replace a defective dc-converter board with a

new one.

Follow this procedure to open the pattern control unit to access the

dc-converter board.

WARNING:

Risk of equipment damage or personal injury.

Disconnect and lock out electrical power to the unit.

1. Turn off power to the unit.

2. See Figure 1. Remove the three screws that secure the terminal

block cover to the unit; then pull the terminal block cover down about

25 mm (1 in.) to disengage the tabs and remove it from the unit.

3. Remove the two screws that secure the operator panel assembly to

the mounting plate.

CAUTION:

Risk of equipment damage. To prevent damage to

the cables, take care not to move the operator panel assembly

too far from the main control unit.

4. Rotate the bottom of the operator panel assembly up and

a. Disconnect the serial port cable from X5 on the main control

board.

b. Disconnect the wiring harness from X3 on the dc-converter board.