Kanal-Luftqualitätsfühler (VOC) bzw. Messumformer, 
incl. Montageflansch, selbstkalibrierend, mit Mehrbereichs-
umschaltung und aktivem ⁄ schaltendem Ausgang

G

  

Operating Instructions, Mounting & Installation

Duct air quality sensors (VOC) and measuring transducers, 
including installation flange, self-calibrating, with multi-range 
 switching and active ⁄ switching output

F

  

Notice d’instruction

Sonde de qualité de l'air pour montage en gaine (COV)  
resp. convertisseur de mesure,y compris bride de montage,  
auto-calibrant, avec commutation multi-gamme  
et sortie active ⁄ tout ou rien 

r

  

Руководство по монтажу и обслуживанию

Канальный датчик ⁄ измерительный преобразователь 
качества воздуха (VOC), вкл. присоединительный фланец, 
самокалибрующийся, с переключением между несколькими 
диапазонами и активным ⁄ релейным выходом

KLQ - W 

(IP 65)

KLQ - SD 

  (IP 54)

CARTONS 

ET EMBALLAGE 
PAPIER À TRIER

6000-3770-000-1XX

  37700-2021  V107

    03  ⁄  2021

S+S REGELTECHNIK GMBH 
THURN-UND-TAXIS-STR. 22 
90411 NÜRNBERG ⁄ GERMANY 
FON +49 (0) 911 ⁄ 5 19  47- 0
[email protected] 
www.SplusS.de

Summary of Contents for Aerasgard KLG-W

Page 1: ...uding installation flange self calibrating with multi range switching and active switching output F Notice d instruction Sonde de qualit de l air pour montage en gaine COV resp convertisseur de mesure...

Page 2: ...en mati re plastique Montageschema Mounting diagram Sch ma de montage 250 mm 115 mm 250 mm 115 mm Ma zeichnung Dimensional drawing Plan cot KLQ W KLQ SD KLQ W KLQ SD 14 8 37 8 M16x1 5 32 3 12 13 4 20...

Page 3: ...Ausgang 0 V saubere Luft 10 V verschmutzte Luft KLQ SD 0 10 V fest eingestellt KLQ W 0 10 V oder 4 20 mA B rde 800 ber DIP Schalter w hlbar mit Offset Potentiometer 10 vom Messbereich Relais Ausgang K...

Page 4: ...den um eine schnellere Anpassung des Korrekturwertes zu erreichen Manuelle Kalibrierung der Luftqualit t Vor und w hrend des Kalibriervorganges ist f r ausreichend Frischluft zu sorgen Wir empfehlen e...

Page 5: ...betriebnahme ist diese Anleitung zu lesen und die alle darin gemachten Hinweise sind zu beachten Der Anschluss der Ger te darf nur an Sicherheitskleinspannung und im spannungslosen Zustand erfolgen Um...

Page 6: ...0 10 V or 4 20 mA working resistance 800 selectable via DIP switches with offset potentiometer 10 of the measuring range Relay output KLQ SD without changeover contact KLQ W with potential free change...

Page 7: ...ration to adjust the correction value more quickly Manual calibration of air quality Sufficient fresh air must be provided before and after the calibration procedure We recommend a fresh air supply of...

Page 8: ...onditions In addition the following points are to be observed These instructions must be read before installation and putting in operation and all notes provided therein are to be regarded Devices mus...

Page 9: ...Quality Qualit de l air int rieur Sortie 0 V air propre 10 V air pollu KLQ SD 0 10 V r glage fixe KLQ W 0 10 V ou 4 20 mA charge 800 s lectionnable via interrupteur DIP avec potentiom tre offset 10 de...

Page 10: ...e correction soit adapt e plus rapidement talonnage manuel de la qualit de l air Avant et pendant le processus d talonnage assurer une alimentation en air frais suffisante Nous recommandons une alimen...

Page 11: ...e attentivement la pr sente notice et toutes les consignes qui y sont pr cis es Les raccordements lectriques doivent tre ex cut s HORS TENSION Ne branchez l appareil que sur un r seau de tr s basse te...

Page 12: ...1 A 20 60 1 1 0 3 10 60 C 0 14 1 5 30 RAL 9016 KLQ SD KLQ W 72 x 64 x 37 8 Tyr 1 Tyr 01 M 16 x 1 5 10 4 M12 DIN EN 61076 2 101 PLEUROFORMTM PA6 20 NL 202 5 vmax 30 III EN 60 730 KLQ SD IP54 EN 60 529...

Page 13: ...59 4 60 79 5 80 100 TVOC Bundesgesundheitsbl Gesundheitsforsch Gesundheitsschutz 2007 50 990 1005 DIP KLQ W VO DIP1 DIP2 LOW OFF OFF MEDIUM default ON OFF HIGH OFF ON IAQ Indoor Air Quality ON ON DIP...

Page 14: ...10 0 UB 15 36 UB GND 24 Circuitry Circuitry Output 0V GND Output 0V GND Power supply AC 24V 0V DC 15 36V GND Circuitry Output 0V GND Power supply AC 24V 0V DC 15 36V GND VOC 10 95 0 50 C VOC ZVEI VDE...

Page 15: ...plication potential but do not imply any warranty as to certain product characteristics Since the devices are used under a wide range of different conditions and loads beyond our control their particu...

Page 16: ...Luftg te 0 10V 4 20mA UB GND ffner Schlie er Wechsler 24V 1A 1 2 3 12 11 13 UB 24V AC DC Output air quality 0 10V 4 20mA UB GND Breaker changeover 24V 1A Normally open contact 1 2 3 4 ON DIP SET Zero...