background image

3 – English

ELECTRICAL

EXTENSION CORDS

When using a product at a considerable distance from a 
power source, be sure to use an extension cord that has 
the capacity to handle the current the product will draw. An 
undersized cord will cause a drop in line voltage, resulting in 
overheating and loss of power. Use the chart to determine 
the minimum wire size required in an extension cord. Only 
round jacketed cords listed by Underwriter’s Laboratories 
(UL) should be used.
When using this product outdoors, use an extension cord that 
is designed for outside use. This type of cord is designated 
with “WA” or “W” on the cord’s jacket.
Before using any extension cord, inspect it for loose or 
exposed wires and cut or worn insulation.

**Ampere rating (on product data plate)

 

 

0-2.0 

2.1-3.4 

3.5-5.0  5.1-7.0  7.1-12.0   12.1-16.0

Cord Length   

 Wire Size (A.W.G.)

 

25´ 16  16 16 16 14  14

 

50´ 16  16 16 14 14  12

 

100´ 16  16 14 12 10  —

**Used on 12 gauge - 20 amp circuit

NOTE: 

AWG = American Wire Gauge

WARNING: 

Keep the extension cord clear of the working area. 
Position the cord so that it will not get caught on lumber, 
tools, or other obstructions while you are working with 
this product. Failure to do so can result in serious 
personal injury.

WARNING: 

Check extension cords before each use. If damaged 
replace immediately. Never use a product with a damaged 
cord since touching the damaged area could cause 
electrical shock resulting in serious injury.

DOUBLE INSULATION

Double insulation is a concept in safety in electric products, 
which eliminates the need for the usual three-wire grounded 
power cord. All exposed metal parts are isolated from the 
internal metal components with protecting insulation. Double 
insulated products do not need to be grounded.

WARNING: 

The double insulated system is intended to protect the 
user from shock resulting from a break in the product’s 
internal wiring. Observe all normal safety precautions to 
avoid electrical shock.

NOTE:

 Servicing of a product with double insulation requires 

extreme care and knowledge of the system and should 
be performed only by a qualified service technician. For 
service, we suggest you return the product to your nearest 
authorized service center for repair. Always use original 
factory replacement parts when servicing.

ELECTRICAL CONNECTION

This is a hybrid product capable of operating on alternating 
current (AC) through an extension cord or direct current (DC) 
through a battery pack. If the product does not operate when 
an extension cord or battery pack is installed, double-check 
the power supply.

 

To use alternating current, connect the product to a 

power 

supply that is 120 volts, AC only (normal household 
current), 60 Hz. 

 

To use direct current, install a 

manufacturer-

recommended 18 volt battery pack only

 

NOTE:

 Do not operate this product on direct current 

through an extension cord. Doing so would cause a 
substantial voltage drop, which will cause a loss of power 
and could cause the product to overheat. 

Summary of Contents for VOLT ONE+ P790

Page 1: ...lemanueld utilisationavant d employer ce produit GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS TABLE OF CONTENTS Important Safety Instructions 2 Electrical 3 Symbols 4 Assembly 5 Operation 5 6 Maintenance...

Page 2: ...n to use light lens and surrounding housing Keep light dry clean and free from oil and grease Always use a clean cloth when cleaning Never use brake fluids gasoline petroleum based products or any str...

Page 3: ...trical shock resulting in serious injury DOUBLE INSULATION Double insulation is a concept in safety in electric products which eliminates the need for the usual three wire grounded power cord All expo...

Page 4: ...atteries in ordinary trash Consult your local waste authorityforinformation regardingavailablerecyclingand ordisposaloptions V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second W Wa...

Page 5: ...ess fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recom mended by the manufacturer of this product The use of attachments or access...

Page 6: ...lows for for additional hanging options Twist the free end into the keyhole on top of the light Pull the hook upward and hang in the desired location To close the hook place the open end in the hole a...

Page 7: ...sing solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use NOTICE The LEDs cannot be replaced Any attem...

Page 8: ...URIT Ne jamais utiliser de liquide de freins d essence de produits base de p trole ou de solvants puissants pour nettoyer la lampe Ne pas exposer la projecteur la pluie La p n tration d eau dans des o...

Page 9: ...s produits double isolation ne n cessitent pas de mise la terre AVERTISSEMENT Le syst me double isolation est con u pour prot ger l utilisateur contre les chocs lectriques caus s par une rupture du c...

Page 10: ...as en la basura normal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y desecho disponibles V Volts Tension A Amp res Intens...

Page 11: ...utils hybrides sont toujours en tat de marche Cependant l appareil doit toujours tre en position d arr t d en avoir retir le bloc pile et d avoir d branch le cordon d alimentation d s la fin de son ut...

Page 12: ...e r glables lorsque de son positionnement pour viter les pincements La t te de la lampe tourne verticalement 180 Elle tourne en sens horaire et anti horaire 180 INSTALLATION RETRAIT DU BLOC PILES Voir...

Page 13: ...a lampe de travail DEL dans un endroit sans fils lectriques o se trouvent des c bles de service utilitaire ou d autres obstructions peuvent s y retrouver Communiquer avec l entreprise de service d uti...

Page 14: ...un pa o limpio para limpiar la unidad Nunca utilice fluidos para frenos gasolina productos a base de petr leo ni disolventes fuertes para limpiar el luz de rea No exponga el luz de rea a la lluvia El...

Page 15: ...asexpuestasest n aisladas de los componentes met licos internos por medio de aislamiento de protecci n No es necesario conectar a tierra las producto con doble aislamiento ADVERTENCIA El sistema de do...

Page 16: ...har las bater as en la basura normal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y desecho disponibles V Voltios Voltaje A...

Page 17: ...as herramientas h bridas siempre est n en condiciones de funcionamiento Por lo tanto la unidad siempre debe estar APAGADA con el paquete de bater as extra do y el cable desconectado cuando no est en u...

Page 18: ...o para evitar posibles pellizcos El cabezal de la l mpara puede rotar de forma vertical 180 Puede rotar en sentido horario o antihorario 180 ADVERTENCIA Retire siempre el paquete de bater as o cord n...

Page 19: ...amente cuelgue o monte la luz de trabajo LED en un rea donde no haya cables el ctricos cables de servicios p blicos tuber as ni otros obst culos Comun quese con su compa a local de servicios p blicos...

Page 20: ...k bloc piles paquete de bater as C Battery port logements de piles puertos de bater as C B A B C A Adjustable head t te de r glage cabeza ajuste B 180 Rotation rotation sur 180 rotaci n de 180 C 180 R...

Page 21: ...NOTES NOTAS...

Page 22: ...NOTES NOTAS...

Page 23: ...NOTES NOTAS...

Page 24: ...ir des pi ces de rechange trouver un Centre de r parations agr pour obtenir un soutien technique ou le Service la client le Visiter www ryobitools com ou en t l phonant au 1 800 525 2579 Si des pi ces...

Reviews: