background image

6 – English

OPERATION

POWER BUTTON 

See Figure 3, page 8.

The light will be in the OFF position until the power button 
is pressed.

 

Connect the product to an AC or DC power supply.

 

Press and release the power button three times to cycle 
through high, medium, and low brightness levels.

 

Press and release the power button a fourth time to turn 
the light OFF.

NOTE: 

This light is equipped with a low voltage indicator. If 

the light flashes 3 times while a battery pack is installed, this 
indicates a low charge condition. Three additional flashes 
indicate that shutdown will follow quickly. Install a charged 
battery pack and resume operation. 

ADJUSTABLE HEAD

See Figure 4, page 8.

CAUTION:

Do not place hands or fingers between adjustable head 
and frame when positioning light to avoid pinching your 
fingers or hands.

The light head can rotated vertically 180

°

. It can be rotated 

clockwise or counterclockwise 180

°

.

HANGING THE LIGHT

See Figure 5, page 8.

WARNING:

Only hang or mount LED light in an area where no 
electrical wires, utility cables, pipes, or other obstructions 
are located. Contact your local utility company or a 
qualified electrician if you are unsure. Do not hang light 
from any electrical power cord. Ensure light is securely 
installed to prevent falling object hazard. Failure to follow 
these instructions can result in electrocution, electrical 
shock, or other serious personal injury.

  The light can be hung by its hook.  

 

NOTE: 

Be careful not to hang the light in such a way 

that it prevents normal operation or damages the cord.

  The hook allows for for additional hanging options. Twist 

the free end into the keyhole on top of the light. Pull the 
hook upward and hang in the desired location. To close 
the hook, place the open end in the hole and push until 
it clicks into place.

  You may use a screw to secure the light in place. Do 

not overtighten. 

INSTALLING/REMOVING BATTERY PACK

See Figure 1, page 8.

  Insert the battery pack into the product as shown.

  Make sure the latches on each side of the battery pack 

snap into place and the battery pack is secured before 
beginning operation.

  Depress the latches to remove the battery pack.

For complete charging instructions, refer to the Operator’s 
Manuals for your battery pack and charger models.

WARNING:

Always remove battery pack or unplug extension cord 
from the product when you are assembling parts, mak-
ing adjustments, cleaning, or when not in use. Remov-
ing battery pack and unplugging the extension cord will 
prevent accidental starting that could cause serious 
personal injury.

INSTALLING/REMOVING POWER CORD

See Figure 2, page 8.

WARNING:

Do not route cord under carpets, rugs, runners, furniture, 
or appliances and always route cord away from traffic 
areas to prevent a tripping hazard.

  Remove the battery pack.

  Insert the female end of the power cord into the product 

as shown.

  Connect the male end of the power cord to the power 

source.

  Make sure the power cord is secured before beginning 

operation.

WARNING:

Keep light away from combustible materials. If wrapped 
or in contact with fabrics, the lens can produce sufficient 
heat to melt some fabrics. To avoid serious personal 
injury, never allow the lens to come in contact with 
anything.

MAGTRAY

The MAGTRAY

, located on the base of the light, conveniently 

stores screws or other small parts.

Summary of Contents for VOLT ONE+ P790

Page 1: ...lemanueld utilisationavant d employer ce produit GUARDE ESTE MANUAL PARA FUTURAS CONSULTAS TABLE OF CONTENTS Important Safety Instructions 2 Electrical 3 Symbols 4 Assembly 5 Operation 5 6 Maintenance...

Page 2: ...n to use light lens and surrounding housing Keep light dry clean and free from oil and grease Always use a clean cloth when cleaning Never use brake fluids gasoline petroleum based products or any str...

Page 3: ...trical shock resulting in serious injury DOUBLE INSULATION Double insulation is a concept in safety in electric products which eliminates the need for the usual three wire grounded power cord All expo...

Page 4: ...atteries in ordinary trash Consult your local waste authorityforinformation regardingavailablerecyclingand ordisposaloptions V Volts Voltage A Amperes Current Hz Hertz Frequency cycles per second W Wa...

Page 5: ...ess fraction of a second is sufficient to inflict serious injury WARNING Do not use any attachments or accessories not recom mended by the manufacturer of this product The use of attachments or access...

Page 6: ...lows for for additional hanging options Twist the free end into the keyhole on top of the light Pull the hook upward and hang in the desired location To close the hook place the open end in the hole a...

Page 7: ...sing solvents when cleaning plastic parts Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use NOTICE The LEDs cannot be replaced Any attem...

Page 8: ...URIT Ne jamais utiliser de liquide de freins d essence de produits base de p trole ou de solvants puissants pour nettoyer la lampe Ne pas exposer la projecteur la pluie La p n tration d eau dans des o...

Page 9: ...s produits double isolation ne n cessitent pas de mise la terre AVERTISSEMENT Le syst me double isolation est con u pour prot ger l utilisateur contre les chocs lectriques caus s par une rupture du c...

Page 10: ...as en la basura normal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y desecho disponibles V Volts Tension A Amp res Intens...

Page 11: ...utils hybrides sont toujours en tat de marche Cependant l appareil doit toujours tre en position d arr t d en avoir retir le bloc pile et d avoir d branch le cordon d alimentation d s la fin de son ut...

Page 12: ...e r glables lorsque de son positionnement pour viter les pincements La t te de la lampe tourne verticalement 180 Elle tourne en sens horaire et anti horaire 180 INSTALLATION RETRAIT DU BLOC PILES Voir...

Page 13: ...a lampe de travail DEL dans un endroit sans fils lectriques o se trouvent des c bles de service utilitaire ou d autres obstructions peuvent s y retrouver Communiquer avec l entreprise de service d uti...

Page 14: ...un pa o limpio para limpiar la unidad Nunca utilice fluidos para frenos gasolina productos a base de petr leo ni disolventes fuertes para limpiar el luz de rea No exponga el luz de rea a la lluvia El...

Page 15: ...asexpuestasest n aisladas de los componentes met licos internos por medio de aislamiento de protecci n No es necesario conectar a tierra las producto con doble aislamiento ADVERTENCIA El sistema de do...

Page 16: ...har las bater as en la basura normal Consulte a las autoridades reguladoras de desechos para obtener informaci n en relaci n con las alternativas de reciclado y desecho disponibles V Voltios Voltaje A...

Page 17: ...as herramientas h bridas siempre est n en condiciones de funcionamiento Por lo tanto la unidad siempre debe estar APAGADA con el paquete de bater as extra do y el cable desconectado cuando no est en u...

Page 18: ...o para evitar posibles pellizcos El cabezal de la l mpara puede rotar de forma vertical 180 Puede rotar en sentido horario o antihorario 180 ADVERTENCIA Retire siempre el paquete de bater as o cord n...

Page 19: ...amente cuelgue o monte la luz de trabajo LED en un rea donde no haya cables el ctricos cables de servicios p blicos tuber as ni otros obst culos Comun quese con su compa a local de servicios p blicos...

Page 20: ...k bloc piles paquete de bater as C Battery port logements de piles puertos de bater as C B A B C A Adjustable head t te de r glage cabeza ajuste B 180 Rotation rotation sur 180 rotaci n de 180 C 180 R...

Page 21: ...NOTES NOTAS...

Page 22: ...NOTES NOTAS...

Page 23: ...NOTES NOTAS...

Page 24: ...ir des pi ces de rechange trouver un Centre de r parations agr pour obtenir un soutien technique ou le Service la client le Visiter www ryobitools com ou en t l phonant au 1 800 525 2579 Si des pi ces...

Reviews: