background image

3

 WARNING

Servicing requires extreme care and knowledge 

and  should  be  performed  only  by  a  qualified  service 

technician. For service we suggest you return the 

product to your nearest authorised service centre for 

repair. When servicing, use only identical replacement 

parts.

 

You may perform maintenance tasks described in 

this manual. For repairs, return the log splitter to an 

authorised service centre.

 WARNING

Hydraulic oil at high pressure is dangerous. Never turn 

on the machine if oil is leaking.

 

Disconnect the product from the power source 

before cleaning, making adjustments, or conducting 

maintenance work on the product.

 

Before each use, check the product for oil leaks and 

other damage. Do not use the log splitter until oil leak or 

damage has been professionally repaired.

 

Keep the product clean, particularly in the splitting area 

and around the motor to ensure adequate ventilation. 

Use a soft brush for cleaning.

 

Before each use, check the oil level and fill if necessary 

using hydraulic oil. Follow the procedure shown in the 

Getting started section. 

 

The manufacturer recommends to change the hydraulic 

oil every 150 hours of use, or if the oil appears dirty or 

contaminated while checking the oil level. 

 

To improve efficiency, regularly check that the fixed 

wedge is not damaged. You may file the edge of the 

fixed wedge as shown in the graphical maintenance 

section of this manual. If the fixed wedge is too badly 

damaged, bring the product to an authorised service 

centre for a replacement fixed wedge.

RESIDUAL RISKS

Even when the product is used as prescribed, it is still 

impossible to completely eliminate certain residual risk 

factors. The following hazards may arise in use and the 

operator should pay special attention to avoid the following:

 

Foot injury from falling debris. Follow size and shape 

limits. Wear protective footwear.

 

Injury caused by entrapment between fixed and moving 

parts. Keep hands and all body parts away from moving 

parts. Only one person allowed to load and operate the 

machine.

 WARNING

Injuries may be caused, or aggravated, by prolonged 

use of the product. When using any tool for prolonged 

periods, ensure you take regular breaks.

KNOW YOUR PRODUCT

See page 6.

1.  Hydraulic ram

2.  Fixed wedge

3.  Log supports

4.  Moving pressure plate

5.  Direction control lever

6.  Control box

7.  Bleed screw

8.  On/Off button

9.  Dipstick with oil drain bolt

SYMBOLS ON THE PRODUCT

Read and understand all instructions 

before operating the product, follow all 

warnings and safety instructions.

The log splitter must be always 

operated by one person only. Keep all 

bystanders, especially children and 

pets away from the operating area.

Wear eye protection.

Wear non-slip safety footwear when 

using the product.

Wear non-slip, heavy-duty gloves.

Beware of electric shock hazard.

Remove plug from the mains 

immediately before maintenance or if 

cable is damaged or cut.

Do not place your hand between the 

fixed wedge and the log

Do not expose the product to rain or 

damp locations.

Remove plug from the mains 

immediately before maintenance or if 

cable is damaged or cut.

Loosen the wing nut during use for 1 to 

2 turns. Retighten during transport.

Regulatory Compliance Mark (RCM).

Product meets applicable regulatory

requirements.
Waste electrical products should not 

be disposed of with household waste. 

Please recycle where facilities exist. 

Check with your local authority or 

retailer for recycling advice.

Summary of Contents for RLS2200T5

Page 1: ...ORIGINAL INSTRUCTIONS Electric Log Splitter RLS2200T5 ...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 3: ...p the motor Keep work area clean Cluttered areas invite accidents Do not leave tools or pieces of wood on the product while it is in operation Keep the operator zone and adjacent area clear for safe secure footing Make sure the work area has ample lighting to see the work and that no obstructions will interfere with safe operation before using the product Make sure the product is on a level surfac...

Page 4: ...rforming splitting operations start the product by pressing the motor run button Move the direction control lever This will cause the pressure plate to move Ensure that by releasing either the motor run button or the direction control lever the motion of the pressure plate stops Do not use the product if this safety feature does not operate properly The wood should be straight along its length wit...

Page 5: ...pletely eliminate certain residual risk factors The following hazards may arise in use and the operator should pay special attention to avoid the following Foot injury from falling debris Follow size and shape limits Wear protective footwear Injury caused by entrapment between fixed and moving parts Keep hands and all body parts away from moving parts Only one person allowed to load and operate th...

Page 6: ...roduct DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION Without safety alert symbol Indicates a situation...

Page 7: ...5 ...

Page 8: ...6 6 4 3 2 7 9 1 5 8 8 ...

Page 9: ...7 360 720 1 7 2 8 1 2 9 3 10 4 1 2 5 6 11 ...

Page 10: ...8 ...

Page 11: ...9 p 10 p 19 p 15 p 19 p 16 p 13 ...

Page 12: ...10 x2 25 cm 52 cm 20 cm 10 cm ...

Page 13: ...11 1 1 2 3 ...

Page 14: ...12 2 3 4 5 ...

Page 15: ...13 2 1 3 3 ...

Page 16: ...14 3 4 5 ...

Page 17: ...15 2 1 1 ...

Page 18: ...16 2 2 2 3 2 4 1 1 3 2 ...

Page 19: ...17 3 5 L HYDRAULIC OIL 1 2 5 4 6 7 ...

Page 20: ...18 20160506v1 8 ...

Page 21: ...19 1 2 1 x2 1 2 ...

Page 22: ...tage 230 240 V 50 Hz Input power 2 200 W S3 25 Motor no load speed 2 800 min Weight 45 kg Maximum log capacity diameter 250 mm Minimum log capacity diameter 100 mm Maximum log capacity length 520 mm Minimum log capacity legth 200 mm Compatible hydraulic oil sold separately Shell Tellus 22 Mobil DTE11 Aral Vitam GF22 or BP Energol HLP HM22 ...

Page 23: ......

Page 24: ...Imported by Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Australia Techtronic Industries New Zealand Ltd 2 Landing Drive Mangere Auckland New Zealand 2022 ...

Reviews: