background image

3

English |

 

Original instructions

 

 WARNING

Service and maintenance require extreme care and 

NQRZOHGJHDQGVKRXOGEHSHUIRUPHGRQO\E\DTXDOL¿HG

service technician. For service and repair, contact an 
authorised service centre. When servicing, use only 
original manufacturer’s replacement parts, accessories, 
and attachments.

 

Ŷ

Do not make adjustments and repairs not described in 
this manual. For other repairs, contact an authorised 
service centre.

 

Ŷ

Before performing any maintenance, stop the engine 
and ensure the engine/choke lever is in the off position. 
Ensure the engine and exhaust of the product has 
cooled down. Failure to heed this warning could result 
in serious personal injury or could damage the product.

 

 WARNING

Protection switches or circuit breakers are vital for safety 
and may only be replaced by an authorised service 
centre.

 

Ŷ

Keep the product in a clean and dry environment where 
it is not exposed to dust, dirt, moisture, or corrosive 
vapours. Do not allow the cooling air slots in the 
generator to become clogged with foreign material such 
as leaves, and snow.

 

Ŷ

Do not use a garden hose to clean the product. Water 
entering the fuel system or other internal parts of the 
product can cause problems that will decrease the life 
of the product.

SYMBOLS ON THE PRODUCT

Do not expose to rain or use in 
damp locations.

To reduce the risk of injury, the 
user must read and understand the 
operator’s manual before using the 
product.

Precautions that involve your safety.

Always wear safety goggles or safety 
glasses with side shields and, as 
necessary, a full face shield when 
operating this product.
Failure to use in dry conditions and 
to observe safe practices can result 
in electric shock.
Running the generator gives off 
carbon monoxide, an odourless, 
colourless, poison gas. Breathing 
carbon monoxide can cause 
nausea, fainting, or death.
Fuel and its vapours are extremely 

ÀDPPDEOHDQGH[SORVLYH)LUHRU

explosion can cause severe burns 
or death.

To reduce the risk of injury or 
damage, avoid contact with any hot 
surface.

Consult with local electrician 
to determine the grounding 
requirements before operation.

Fuel and its vapors are explosive and 
can cause severe burns or death.

Turn the fuel valve to the on or off 
position.

RUN

CHOKE

Turn the choke lever to the start or 
run position.

91 dB

72 dB

Guaranteed sound pressure level is 
72 dB.
Guaranteed sound power level is 91 
dB.

Add lubricant

Do not twist the oil cap when adding 
engine lubricant or when checking the 
lubricant level.
After adding the lubricant or checking 
the lubricant level, replace and ensure 
that the oil cap is securely placed.

Gasoline fuel only.
Do not use diesel fuel.

MUFFLER

HOT

Hot muffler

Do not use the product indoors.

Only run the product outdoors.

Regulatory Compliance Mark (RCM).
Product meets applicable regulatory
requirements.

The following signal words and meanings are intended to 
explain the levels of risk associated with the product.

 

DANGER

Indicates an imminently hazardous situation, which, if 
not avoided, will result in death or serious injury.

 WARNING

Indicates a potentially hazardous situation, which, if not 
avoided, could result in death or serious injury.

 

CAUTION

Indicates a potentially hazardous situation, which, if not 
avoided, may result in minor or moderate injury.

Summary of Contents for RGN2500B

Page 1: ...ORIGINAL INSTRUCTIONS Low Power Generating Set RGN2500B ...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 3: ...r 8 Fuel cap 9 Fuel tank 10 Oil fill hole 11 Oil cap dipstick removed 12 Fuel valve 13 Fuel valve on 14 Fuel valve off 15 Choke lever 16 To start choke closed 17 To run choke open 18 Screw 19 Spark plug 20 Spark plug cap 21 Fuel line 22 Wheel 23 Axle 24 Washer 25 Hitch pin 26 Screws 27 Leg 28 Lock nut 29 Frame handle folded 30 Frame handle unfolded KNOW YOUR PRODUCT ...

Page 4: ...Fig 4 Fig 5 Fig 6 11 8 9 6 10 Fig 7 Fig 8 16 15 13 12 17 14 ...

Page 5: ...Fig 9 7 13 12 14 Fig 10 2 Fig 11 20 19 18 21 Fig 12 ...

Page 6: ...Fig 13 Fig 15 Fig 16 Fig 17 Fig 14 22 28 26 27 29 24 25 23 30 ...

Page 7: ...C 240V AC 240V ON OFF OIL ALERT LAMP 9 1 2 3 4 8 7 6 5 Fig 18 CONTROL PANEL LABEL See figure 18 1 Multimeter 2 Circuit breaker 3 AC receptacle 4 AC receptacle 5 PE Terminal 6 Oil alert lamp 7 Engine switch off 8 Engine switch on 9 Engine switch ...

Page 8: ...he transfer switch have been properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes Ŷ Do not allow children or untrained individuals to use the product Protect children by keeping them at a safe distance from the generator set Ŷ Do not ...

Page 9: ...ypes of combustible material Ŷ Do not touch the muffler or cylinder during or immediately after use they are hot and will cause burn injury Ŷ Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician Ŷ Do not allow the generator s gas tank to overflow when filling Fill to 25 mm 1 below the top neck of the gas tank to allow for ...

Page 10: ...shields and as necessary a full face shield when operating this product Failure to use in dry conditions and to observe safe practices can result in electric shock Running the generator gives off carbon monoxide an odourless colourless poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapours are extremely ÀDPPDEOH DQG H SORVLYH LUH RU explosion can cause severe ...

Page 11: ...H KHDW IURP WKH PXIÀHU LJQLWLQJ IXHO YDSRXUV ENGINE LUBRICANT WARNING RX PXVW DGG RLO EHIRUH UVW RSHUDWLQJ WKH JHQHUDWRU Always check the oil level before each operation The oil level should always register within the hatched area on the dipstick The product is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit HOT SURFACE WARNING R QRW W...

Page 12: ...utput of the generator Motor Size HP Running Watts Watts required to start motor Universal Capacitor Split phase 1 8 275 N A 850 1200 1 6 275 600 850 2050 1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 CAUTION Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator Dam...

Page 13: ... sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator output to stabilise engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilise 6 ...

Page 14: ... box and carefully slide out the generator and any accessories NOTE The generator is heavy If you must lift the product out of the box get another person to help you and lift with your legs not your back Ŷ Inspect the product carefully to make sure no damage occurred during shipping Ŷ Do not discard the packing material until you have carefully inspected and satisfactorily operated the product Ŷ I...

Page 15: ...r 2 stroke engine lubricants will damage the engine and should not be used Ŷ Unscrew the oil cap dipstick and remove Ŷ Wipe dipstick clean and re seat in hole do not re thread Ŷ Remove dipstick again and check lubricant level Lubricant level should fall between the minimum and maximum marks on the dipstick Ŷ If level is low add engine lubricant until the fluid level rises between the minimum and m...

Page 16: ...y situation Ŷ Put the engine switch in the OFF O position WARNING While operating and storing keep at least 1 m of clearance on all sides of the product including overhead Allow a minimum of 30 minutes of cool down time EHIRUH VWRUDJH HDW FUHDWHG E PXIÀHU DQG H KDXVW gases could be hot enough to cause serious burns and or ignite combustible objects USING THE GENERATOR Connect devices to be powered...

Page 17: ...sult in serious burns SPARK PLUG MAINTENANCE See figure 11 The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check Ŷ Remove the spark plug cap Ŷ Clean any dirt from around base of spark plug Ŷ Remove spark plug using wrench provided Ŷ Inspect spark plug for damage and clean with a wire brush before reinstalling If insulator is cracked or chip...

Page 18: ...f Load 16 78 hrs Approvals AS NZS 3010 Yes Euro Emission Yes EMC Yes Uncertainty dB 2 25 Noise level 4 m LpA dB A 69 01 Noise level 7 m LpA dB A 72 Noise level LwA dB A 91 TRANSPORTING Ŷ Turn engine switch OFF O Ŷ Close the fuel valve Ŷ Make sure the engine and the exhaust of the product has cooled down Ŷ Keep the product level to prevent fuel spillage Ŷ Do not drop or strike the product or place ...

Page 19: ...Turn ON the AC circuit breaker Item plugged in is defective Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging under heavy load is not a cause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand of unleaded f...

Page 20: ... adjust idle speed Check adjust valve clearance 1 OHDQ IXHO WDQN DQG OWHU 1 Check fuel hose XHO OWHU Inspect Replace Check all hose connections Inspect fuel tank vapor vent if equipped Inspect carbon canister CARB models only 1 These items should only be carried out by an authorised service centre NOTE Maintenance should be performed more frequently when generator is used in dusty areas When gener...

Page 21: ...WIRING DIAGRAM ...