background image

8

 Original 

instructions

 

| English

 

OPERATION

 

 WARNING

Do not allow familiarity with tools to make you careless. 
Remember that a careless fraction of a second is 

VXI¿FLHQWWRLQÀLFWVHULRXVLQMXU\

 

 WARNING

Do not use any attachments or accessories not 
recommended by the manufacturer of the product. The 
use of attachments or accessories not recommended 
can result in serious personal injury.

APPLICATIONS

This generator is designed to supply electrical power for 
operating compatible electrical lighting, appliances, tools, 
and motor loads.

BEFORE OPERATING THE PRODUCT

 

Ŷ

Only use outdoors and far away from windows, doors, 
and vents.

 

Ŷ

Never use inside a home or garage, even if the doors 
and windows are open.

 

Ŷ

Always position the generator on a flat firm surface.

 

Ŷ

Check engine lubricant level and fill, if necessary. Refer 
to the "CHECKING/ADDING LUBRICANT" section in 
this manual.

 

Ŷ

Check fuel level and fill, if necessary. Refer to the 
"CHECKING/ADDING FUEL" section in this manual.

 

 CAUTION

Attempting to start the engine before it has been properly 

¿OOHGZLWKRLOZLOOUHVXOWLQHTXLSPHQWIDLOXUH

SPECIAL REQUIREMENTS:

3OHDVH FRQVXOW D TXDOL¿HG HOHFWULFLDQ HOHFWULFDO LQVSHFWRU

or the local agency having jurisdiction.

 

Ŷ

In some areas, generators are required to be registered 
with local utility companies.

 

Ŷ

If the generator is used at a construction site, there may 
be additional regulations which must be observed.

CHECKING/ADDING LUBRICANT

See figure 4

 

 CAUTION

Attempting to start the engine before it has been properly 

¿OOHG ZLWK RLO ZLOO UHVXOW LQ HTXLSPHQW IDLOXUH (QJLQH
OXEULFDQWKDVDPDMRULQÀXHQFHRQHQJLQHSHUIRUPDQFH

and service life. For general, all-temperature use, SAE 
10W-30 is recommended. Always use a 4-stroke motor 
lubricant that meets or exceeds the requirements for API 

VHUYLFHFODVVL¿FDWLRQ6-

NOTE:

 Non-detergent or 2-stroke engine lubricants will 

damage the engine and should not be used.

 

Ŷ

Unscrew the oil cap/dipstick and remove.

 

Ŷ

Wipe dipstick clean and re-seat in hole; do not re-
thread.

 

Ŷ

Remove dipstick again and check lubricant level. 
Lubricant level should fall between the minimum and 
maximum marks on the dipstick.

 

Ŷ

If level is low, add engine lubricant until the fluid level 
rises between the minimum and maximum marks on the 
dipstick. 

 

Ŷ

Replace and secure the oil cap/dipstick.

CHECKING/ADDING FUEL

See figure 5

 

 WARNING

*DVROLQH DQG LWV YDSRXUV DUH KLJKO\ ÀDPPDEOH DQG

explosive. To prevent serious personal injury and 
property damage, handle gasoline with care. Keep away 
from ignition sources, handle outdoors only, do not 
smoke while adding fuel, and wipe up spills immediately.

When adding fuel to the generator, make sure the product 

LVVLWWLQJRQDÀDWOHYHOVXUIDFH,IWKHHQJLQHLVKRWOHWWKH
JHQHUDWRUFRROGRZQEHIRUHDGGLQJJDV$OZD\V¿OOWKHIXHO

tank outdoors with the product turned off.

 

Ŷ

Remove the fuel cap.

 

Ŷ

Fill the fuel tank to 25 mm below the top of the fuel neck.

 

Ŷ

Replace and secure the fuel cap.

NOTE:

  Always use unleaded gasoline with a pump octane 

rating of 86 or higher. Never use old, stale, or contaminated 
unleaded fuel, and do not use an oil/fuel mixture. Do not 
allow dirt or water into the fuel tank. Do not use E85 fuel.

USING FUEL STABILISER

Fuel gets old, oxidizes, and breaks down over time. Adding 
a fuel stabiliser extends the usable life of fuel and helps 
prevent deposits from forming that can clog the fuel system.
Follow fuel stabiliser manufacturer’s directions for correct 
ratio of stabiliser to fuel.

 

Ŷ

Add stabiliser to fuel tank, then fill with unleaded fuel 
following previous instructions.

NOTE:

 Fuel stabiliser and unleaded fuel can be mixed prior 

to filling the tank by using a gasoline can or other approved 
fuel container and shaking gently to combine.

 

Ŷ

Replace and secure the fuel tank cap.

 

Ŷ

Start and run the engine for at least 5 minutes to allow 
stabiliser to treat the entire fuel system.

Summary of Contents for RGN2500B

Page 1: ...ORIGINAL INSTRUCTIONS Low Power Generating Set RGN2500B ...

Page 2: ...Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modification ...

Page 3: ...r 8 Fuel cap 9 Fuel tank 10 Oil fill hole 11 Oil cap dipstick removed 12 Fuel valve 13 Fuel valve on 14 Fuel valve off 15 Choke lever 16 To start choke closed 17 To run choke open 18 Screw 19 Spark plug 20 Spark plug cap 21 Fuel line 22 Wheel 23 Axle 24 Washer 25 Hitch pin 26 Screws 27 Leg 28 Lock nut 29 Frame handle folded 30 Frame handle unfolded KNOW YOUR PRODUCT ...

Page 4: ...Fig 4 Fig 5 Fig 6 11 8 9 6 10 Fig 7 Fig 8 16 15 13 12 17 14 ...

Page 5: ...Fig 9 7 13 12 14 Fig 10 2 Fig 11 20 19 18 21 Fig 12 ...

Page 6: ...Fig 13 Fig 15 Fig 16 Fig 17 Fig 14 22 28 26 27 29 24 25 23 30 ...

Page 7: ...C 240V AC 240V ON OFF OIL ALERT LAMP 9 1 2 3 4 8 7 6 5 Fig 18 CONTROL PANEL LABEL See figure 18 1 Multimeter 2 Circuit breaker 3 AC receptacle 4 AC receptacle 5 PE Terminal 6 Oil alert lamp 7 Engine switch off 8 Engine switch on 9 Engine switch ...

Page 8: ...he transfer switch have been properly installed and the electrical output has been verified by a qualified electrician The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes Ŷ Do not allow children or untrained individuals to use the product Protect children by keeping them at a safe distance from the generator set Ŷ Do not ...

Page 9: ...ypes of combustible material Ŷ Do not touch the muffler or cylinder during or immediately after use they are hot and will cause burn injury Ŷ Do not connect to a building s electrical system unless a transfer switch has been properly installed by a qualified electrician Ŷ Do not allow the generator s gas tank to overflow when filling Fill to 25 mm 1 below the top neck of the gas tank to allow for ...

Page 10: ...shields and as necessary a full face shield when operating this product Failure to use in dry conditions and to observe safe practices can result in electric shock Running the generator gives off carbon monoxide an odourless colourless poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapours are extremely ÀDPPDEOH DQG H SORVLYH LUH RU explosion can cause severe ...

Page 11: ...H KHDW IURP WKH PXIÀHU LJQLWLQJ IXHO YDSRXUV ENGINE LUBRICANT WARNING RX PXVW DGG RLO EHIRUH UVW RSHUDWLQJ WKH JHQHUDWRU Always check the oil level before each operation The oil level should always register within the hatched area on the dipstick The product is equipped with an oil sensor which will automatically shut off the engine if oil level falls below a safe limit HOT SURFACE WARNING R QRW W...

Page 12: ...utput of the generator Motor Size HP Running Watts Watts required to start motor Universal Capacitor Split phase 1 8 275 N A 850 1200 1 6 275 600 850 2050 1 4 400 800 1050 2400 1 3 450 950 1350 2700 1 2 600 1000 1800 3600 3 4 850 1200 2600 1 1100 N A 3300 CAUTION Operating voltage and frequency requirement of all electronic equipment should be checked prior to plugging them into this generator Dam...

Page 13: ... sequentially add loads as follows 1 With nothing connected to the generator start the engine as described later in this manual 2 Plug in and turn on the first load preferably the largest load highest wattage you have 3 Permit the generator output to stabilise engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilise 6 ...

Page 14: ... box and carefully slide out the generator and any accessories NOTE The generator is heavy If you must lift the product out of the box get another person to help you and lift with your legs not your back Ŷ Inspect the product carefully to make sure no damage occurred during shipping Ŷ Do not discard the packing material until you have carefully inspected and satisfactorily operated the product Ŷ I...

Page 15: ...r 2 stroke engine lubricants will damage the engine and should not be used Ŷ Unscrew the oil cap dipstick and remove Ŷ Wipe dipstick clean and re seat in hole do not re thread Ŷ Remove dipstick again and check lubricant level Lubricant level should fall between the minimum and maximum marks on the dipstick Ŷ If level is low add engine lubricant until the fluid level rises between the minimum and m...

Page 16: ...y situation Ŷ Put the engine switch in the OFF O position WARNING While operating and storing keep at least 1 m of clearance on all sides of the product including overhead Allow a minimum of 30 minutes of cool down time EHIRUH VWRUDJH HDW FUHDWHG E PXIÀHU DQG H KDXVW gases could be hot enough to cause serious burns and or ignite combustible objects USING THE GENERATOR Connect devices to be powered...

Page 17: ...sult in serious burns SPARK PLUG MAINTENANCE See figure 11 The spark plug must be properly gapped and free of deposits in order to ensure proper engine operation To check Ŷ Remove the spark plug cap Ŷ Clean any dirt from around base of spark plug Ŷ Remove spark plug using wrench provided Ŷ Inspect spark plug for damage and clean with a wire brush before reinstalling If insulator is cracked or chip...

Page 18: ...f Load 16 78 hrs Approvals AS NZS 3010 Yes Euro Emission Yes EMC Yes Uncertainty dB 2 25 Noise level 4 m LpA dB A 69 01 Noise level 7 m LpA dB A 72 Noise level LwA dB A 91 TRANSPORTING Ŷ Turn engine switch OFF O Ŷ Close the fuel valve Ŷ Make sure the engine and the exhaust of the product has cooled down Ŷ Keep the product level to prevent fuel spillage Ŷ Do not drop or strike the product or place ...

Page 19: ...Turn ON the AC circuit breaker Item plugged in is defective Try a different item Generator makes a spark knock or pinging noise An occasional light knocking or pinging under heavy load is not a cause for concern However if the knocking or pinging occurs under normal load at a steady engine speed the problem may be with the brand of unleaded fuel being used Switch to a different brand of unleaded f...

Page 20: ... adjust idle speed Check adjust valve clearance 1 OHDQ IXHO WDQN DQG OWHU 1 Check fuel hose XHO OWHU Inspect Replace Check all hose connections Inspect fuel tank vapor vent if equipped Inspect carbon canister CARB models only 1 These items should only be carried out by an authorised service centre NOTE Maintenance should be performed more frequently when generator is used in dusty areas When gener...

Page 21: ...WIRING DIAGRAM ...

Page 22: ......

Page 23: ......

Page 24: ...rted by Techtronic Industries Australia Pty Ltd 31 Gilby Road Mount Waverley VIC 3149 Melbourne Australia Techtronic Industries N Z Limited 2 Landing Drive Mangere Auckland 2022 New Zealand 099979176001 02 ...